Imaging findings in MR imaging-guided focused ultrasound treatment for patients with essential tremor.

نویسندگان

  • M Wintermark
  • J Druzgal
  • D S Huss
  • M A Khaled
  • S Monteith
  • P Raghavan
  • T Huerta
  • L C Schweickert
  • B Burkholder
  • J J Loomba
  • E Zadicario
  • Y Qiao
  • B Shah
  • J Snell
  • M Eames
  • R Frysinger
  • N Kassell
  • W J Elias
چکیده

BACKGROUND AND PURPOSE MR imaging-guided focused sonography surgery is a new stereotactic technique that uses high-intensity focused sonography to heat and ablate tissue. The goal of this study was to describe MR imaging findings pre- and post-ventralis intermedius nucleus lesioning by MR imaging-guided focused sonography as a treatment for essential tremor and to determine whether there was an association between these imaging features and the clinical response to MR imaging-guided focused sonography. MATERIALS AND METHODS Fifteen patients with medication-refractory essential tremor prospectively gave consent; were enrolled in a single-site, FDA-approved pilot clinical trial; and were treated with transcranial MR imaging-guided focused sonography. MR imaging studies were obtained on a 3T scanner before the procedure and 24 hours, 1 week, 1 month, and 3 months following the procedure. RESULTS On T2-weighted imaging, 3 time-dependent concentric zones were seen at the site of the focal spot. The inner 2 zones showed reduced ADC values at 24 hours in all patients except one. Diffusion had pseudonormalized by 1 month in all patients, when the cavity collapsed. Very mild postcontrast enhancement was seen at 24 hours and again at 1 month after MR imaging-guided focused sonography. The total lesion size and clinical response evolved inversely compared with each other (coefficient of correlation = 0.29, P value = .02). CONCLUSIONS MR imaging-guided focused sonography can accurately ablate a precisely delineated target, with typical imaging findings seen in the days, weeks, and months following the treatment. Tremor control was optimal early when the lesion size and perilesional edema were maximal and was less later when the perilesional edema had resolved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive functional neurosurgery using transcranial MR imaging-guided focused ultrasound.

UNLABELLED Transcranial magnetic resonance imaging-guided focused ultrasound (tcMRgFUS) is a novel technique to supplement the spectrum of established neurosurgical interventions. In contrast to traditional ablative procedures, tcMRgFUS is noninvasive and entirely imaging-guided with continuous temperature measurements at and around the target in real time. It has no trajectory restrictions and...

متن کامل

MR guided focused ultrasound as a treatment tool for essential and Parkinsonian tremor

Background/introduction Combining focused ultrasound (FUS) with real time MRI guidance and monitoring enables a new non-invasive treatment of brain disorders. In this technique multisource ultrasound waves are focused at a single point raising the temperature gradually until ablation occurs. Lesions as small as 2-4 mm can be made, without impact on surrounding tissue or remote brain tissue. Our...

متن کامل

Simple MRI metrics contribute to optimal care of the patient with multiple sclerosis.

Cancer Res 2012;72:3652– 63 7. McDannold N, Clement GT, Black P, et al. Transcranial magnetic resonance imaging-guided focused ultrasound surgery of brain tumors: initial findings in 3 patients. Neurosurgery 2010;66:323–32 8. Jeanmonod D, Werner B, Morel A, et al. Transcranial magnetic resonance imaging-guided focused ultrasound: noninvasive central lateral thalamotomy for chronic neuropathic p...

متن کامل

MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study.

BACKGROUND Essential tremor is the most common movement disorder and is often refractory to medical treatment. Surgical therapies, using lesioning and deep brain stimulation in the thalamus, have been used to treat essential tremor that is disabling and resistant to medication. Although often effective, these treatments have risks associated with an open neurosurgical procedure. MR-guided focus...

متن کامل

Bilateral MR imaging-guided high intensity focused ultrasound for the treatment of tremor-dominant Parkinson’s disease: first experience with 9 months follow up

Background/introduction MR imaging-guided high intensity focused ultrasound (MRIgFUS) is a novel, noninvasive technique for the treatment of functional brain disorders through the intact human skull at millimeter precision. The ExAblate 4000 transcranial MRIgFUS system (InSightec, Haifa, Israel) uses a 1024-element phased array transducer, which is attached to the patient’s head via a standard ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 35 5  شماره 

صفحات  -

تاریخ انتشار 2014