Soft-x-ray damage to p-terphenyl coatings for detectors.

نویسندگان

  • E L Benitez
  • M L Dark
  • D E Husk
  • S E Schnatterly
  • C Tarrio
چکیده

The organic phosphor p-terphenyl is used as a wavelength-converter coating in some soft-x-ray detectors. We have measured the absolute photoluminescent efficiency of p-terphenyl as a function of incident photon energy from 36 to 191 eV. We have also measured changes in the efficiency caused by soft-x-ray fluence (total photons absorbed per unit area) at several photon energies in this range. We find that efficiency drops rapidly as a function of fluence, with the rate of decrease increasing with higher soft x-ray energies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

Conformation of p-terphenyl under hydrostatic pressure.

The conformation of p-terphenyl (C18H14) and deuterated p-terphenyl (C18D14) has been investigated, using high-pressure infrared spectroscopy at liquid-helium temperatures. First-principles calculations, together with the experimental results, were performed to determine the structure of p-terphenyl in the twisted conformation. At low temperatures and pressures, p-terphenyl belongs to the C2 po...

متن کامل

X - ray CCDs for Space Applications : Calibration , Radiation Hardness , and Use for Measuring the Spectrum of the Cosmic

This thesis has two distinct components. One concerns the physics of the high energy resolution X-ray Charge Coupled Devices (CCD) detectors used to measure the cosmic Xray background (XRB) spectrum. The other involves the measurements and analysis of the XRB spectrum and instrumental background with these detectors on board the Advanced Satellite for Cosmology and Astrophysics (ASCA). The XRB ...

متن کامل

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

متن کامل

A new X-ray method for residual stress evaluation in coatings

Transition metal nitride coatings films such as TiN or ZrN have been extensively studied for industrial applications. Residual stresses of the coatings generally affect the mechanical behaviour and the corrosion resistance and hence the performance of the product. The development of new, fast and simple methods for the assessment of residual stresses is then of great importance for coating tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 33 10  شماره 

صفحات  -

تاریخ انتشار 1994