Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatographyelectrospray-tandem mass spectrometry.

نویسندگان

  • Sanghoo Lee
  • Soonho Kwon
  • Hye-Jin Shin
  • Jimyeong Park
  • Hwan-Sub Lim
  • Kyoung-Ryul Lee
  • Young-Jin Kim
چکیده

Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-d(3) as an internal standard. The lower limit of quantification (LOQ) was 0.01 ng/ml. The intra- and inter-assay precisions were 1.54% to 4.09% and 0.96% to 4.29%, respectively. The mean recovery was 93.32% (range 88.43-98.05%). The validated assay was then applied to measure the salivary testosterone levels of Korean adults. In men, the salivary testosterone level collected between 9:00-11:00 am was approximately 2.8 times higher than that in women (P < 0.0001). Salivary testosterone levels in both sexes negatively correlated with age. The present assay would also be useful in measuring salivary testosterone levels in clinical laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: validation of a method for routine clinical practice.

BACKGROUND Immunoassay is unsatisfactory for measuring the testosterone concentrations typically found in women. Bench-top tandem mass spectrometers are a viable alternative technology for measurements in the clinical laboratory. METHODS We used stable-isotope dilution liquid chromatography-tandem mass spectrometry (ID/LC-MS/MS) to measure testosterone in plasma and serum. The sample volume w...

متن کامل

Rapid determination of serum testosterone by liquid chromatography-isotope dilution tandem mass spectrometry and a split sample comparison with three automated immunoassays.

OBJECTIVES To develop a rapid convenient-to-implement high performance liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for determination of serum testosterone concentration in routine clinical laboratories. METHODS Following extraction by organic solvents, an Agilent 1200 Series HPLC system coupled to an API 5000 mass spectrometer equipped with an atmospher...

متن کامل

serum testosterone levels measured by ID-LC-MS/MS in postmenopausal women versus those in women who underwent bilateral oophorectomy

Differentiation between subtle changes in low serum testosterone concentrations, common in women and children, is not possible with current commercially available assays. The objectives of the study were to develop a method based on stable isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with adequate sensitivity and specificity and to investigate the applicability ...

متن کامل

Inter-method comparison of salivary cortisol measurement

Background: Salivary cortisol is increasingly used in the diagnostic work-up of suspected Cushing’s disease as well as in stress research. In this study, the agreement of different methods for salivary cortisol measurement was assessed. Methods: Saliva samples from five healthy volunteers were distributed to three routine clinical chemistry laboratories. As a reference, all samples were also an...

متن کامل

Development of a candidate reference method for determination of tyrosine in serum by isotope dilution liquid chromatography-tandem mass spectrometry.

An isotope dilution liquid chromatography/tandem mass spectrometry is proposed as a reference method to determine the level of tyrosine in human serum. The advantages of this method include simple sample preparation without derivatization, the selective detection of compounds of interest in complex matrices, and the use of an isotopically labeled analogue as an internal standard. Tyrosine and i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMB reports

دوره 43 11  شماره 

صفحات  -

تاریخ انتشار 2010