Virtual reality 3D echocardiography in the assessment of tricuspid valve function after surgical closure of ventricular septal defect

نویسندگان

  • Goris Bol Raap
  • Anton HJ Koning
  • Thierry V Scohy
  • A Derk-Jan ten Harkel
  • Folkert J Meijboom
  • A Pieter Kappetein
  • Peter J van der Spek
  • Ad JJC Bogers
چکیده

BACKGROUND This study was done to investigate the potential additional role of virtual reality, using three-dimensional (3D) echocardiographic holograms, in the postoperative assessment of tricuspid valve function after surgical closure of ventricular septal defect (VSD). METHODS 12 data sets from intraoperative epicardial echocardiographic studies in 5 operations (patient age at operation 3 weeks to 4 years and bodyweight at operation 3.8 to 17.2 kg) after surgical closure of VSD were included in the study. The data sets were analysed as two-dimensional (2D) images on the screen of the ultrasound system as well as holograms in an I-space virtual reality (VR) system. The 2D images were assessed for tricuspid valve function. In the I-Space, a 6 degrees-of-freedom controller was used to create the necessary projectory positions and cutting planes in the hologram. The holograms were used for additional assessment of tricuspid valve leaflet mobility. RESULTS All data sets could be used for 2D as well as holographic analysis. In all data sets the area of interest could be identified. The 2D analysis showed no tricuspid valve stenosis or regurgitation. Leaflet mobility was considered normal. In the virtual reality of the I-Space, all data sets allowed to assess the tricuspid leaflet level in a single holographic representation. In 3 holograms the septal leaflet showed restricted mobility that was not appreciated in the 2D echocardiogram. In 4 data sets the posterior leaflet and the tricuspid papillary apparatus were not completely included. CONCLUSION This report shows that dynamic holographic imaging of intraoperative postoperative echocardiographic data regarding tricuspid valve function after VSD closure is feasible. Holographic analysis allows for additional tricuspid valve leaflet mobility analysis. The large size of the probe, in relation to small size of the patient, may preclude a complete data set. At the moment the requirement of an I-Space VR system limits the applicability in virtual reality 3D echocardiography in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right-sided Infective Endocarditis with Multiple Large Vegetations in a Case of Ventricular Septal Defect: A Case Report

Herein, we present the case of a 10-year-old child suffering from right-sided infective endocarditis with ventricular septal defect. Echocardiography revealed multiple rare large vegetations on the pulmonary valve extending into pulmonary artery along with a large vegetation over the septal leaflet of the tricuspid valve. 

متن کامل

Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with...

متن کامل

Three-dimensional echocardiography in adult congenital heart disease

Congenital heart disease (CHD) is now more common in adults than in children due to improvements in fetal echo, neonatal and pediatric care, and surgical techniques leading to dramatically increased survivability into adulthood. Adult patients with CHD, regardless of prior cardiac surgery, experience further cardiac problems or therapeutic challenges; therefore, a non-invasive, easily accessibl...

متن کامل

Echocardiographic criteria for Ebstein's anomaly of tricuspid valve.

Sir, I read with interest the paper by Gussenhoven and her colleagues' on the echocardiographic critieria for Ebstein's anomaly of the tricuspid valve. I agree with their main conclusion that crosssectional echocardiography is better than M-mode echocardiography for making this diagnosis. I am however puzzled by their finding of late tricuspid closure (later than mitral closure by 65 ms or more...

متن کامل

A ball-shaped thrombus of the tricuspid valve after VSD closure.

We report successful surgical management of a 26-year-old man with a ball-shaped thrombus of the tricuspid valve. He had been treated with prednisolone for IgA nephropathy and undergone surgical closure of an isolated ventricular septal defect (VSD). No symptoms, coagulative disorders, or pulmonary embolisms were found. Preoperative echocardiography showed a ball-shaped mass that had originated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2007