Separation of nonsteroidal anti-inflammatory drugs by capillary electrophoresis using nonaqueous electrolytes.

نویسندگان

  • M Fillet
  • I Bechet
  • V Piette
  • J Crommen
چکیده

The aim of the present work was to investigate the separation of nonsteroidal anti-inflammatory drugs (NSAIDs: niflumic acid, flufenamic acid, piroxicam, alclofenac, tiaprofenic acid, flurbiprofen, suprofen, ketoprofen, naproxen, indomethacin, carprofen, indoprofen, sulindac) in capillary electrophoresis (CE) using completely nonaqueous systems. The influence of different parameters such as nature and proportion of organic solvent (methanol, acetonitrile, 2-propanol), apparent pH (ranging from 7 to 9) and temperature (ranging from 25 to 40 degrees C) on selectivity and migration times were studied systematically in an uncoated fused-silica capillary. A nonaqueous electrolyte made of 50 mM ammonium acetate - 13.75 mM ammonia in methanol proved to resolve 11 NSAIDs at 25 degrees C and 13 NSAIDs at 36 degrees C, both within 13 min and without a modifier besides the methanol itself. The same buffer containing 30% acetonitrile provides a satisfactory separation for 13 NSAIDs within 14 min at 25 degrees C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Optimization of the Nonaqueous Capillary Electrophoresis Separation of Metal Ions Using Mixture Design and Response Surface Methods

Mixture experimental design was used to enhance the separation selectivity of metal ions in nonaqueous capillary electrophoresis. The separation of cations (Ag, Fe, Cr, Mn, Cd, Co, Pb, Ni, Zn and Cu) was achieved using imidazole as UV co-ion for indirect detection. Acetic acid was chosen as an electrolyte because its cathodic electroosmotic flow permits faster separation. The composition of org...

متن کامل

Separation of open-cage fullerenes using nonaqueous capillary electrophoresis.

In this study, nonaqueous capillary electrophoresis (NACE) was used to separate three open-cage fullerenes. Trifluoroacetic acid (TFA) was used as the nonaqueous background electrolyte to change the analytes' mobilities. The selectivity and separation efficiency were critically affected by the nature of the buffer system, the choice of organic solvent, and the concentrations of TFA and sodium a...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Single-drop microextraction combined in-line with capillary electrophoresis for the determination of nonsteroidal anti-inflammatory drugs in urine samples.

This study describes a method to determine nonsteroidal anti-inflammatory drugs (NSAIDs) in urine samples based on the use of single-drop microextraction (SDME) in a three-phase design as a preconcentration technique coupled in-line to capillary electrophoresis. Different parameters affecting the extraction efficiency of the SDME process were evaluated (e.g. type of extractant, volume of the mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 1999