RF Sensor Considerations for Input Predistortion Correction of Transmit Arrays

نویسندگان

  • P. Stang
  • M. Zanchi
  • W. Grissom
  • A. Kerr
  • J. Pauly
  • G. Scott
چکیده

Introduction Transmit array systems offer the promise of accelerated excitation, B1 shimming, and the potential for SAR and RF safety management [1,2], while also demanding high-fidelity RF playback in a challenging multi-channel environment. Tx coil arrays are subject to mutual coupling and loading variations, while RF power amplifiers exhibit non-linearity, ill-defined output impedances, and memory effects. We believe precision transmit array control is achievable by input predistortion with mutli-channel loopback sensing. As RF sensors are critical to this technology, we present our on-coil current sensor and in-line vector sensor, and consider the resulting capabilities and limitations in the context of loopback-enabled PTx array control. Parallel Transmit with Loopback Vector Iterative Predistortion (VIP) [3] and Cartesian Feedback (CFB) [4,5] methods enable advanced calibration and linearization of transmit arrays through input predistortion and RF sensing loopback. VIP and CFB capabilities go beyond feed-forward or lookup-table linearization to also address coil decoupling and amplifier memory effects. An example 4-ch TxSENSE parallel excitation illustrates the need for high-fidelity RF and demonstrates VIP correction (Fig 1). While Cartesian feedback and VIP yield identical output coil V & I, they differ in their control architecture and stability constraints. Nonetheless, both methods depend on RF sensors to generate the required feedback signals. To enable these loopback calibration methods, we instrument our MEDUSAbased parallel transmit system with either vector RF power sensors at each power amplifier output, or RF current sensors on each coil (Fig 3). RF Current Sensor Our current sensors are 4-layer PCBs implementing a slotted planar 1:1 transformer, with the outer PCB layers carrying the coil current while squeezing flux to an internal coupled loop (Fig 2b). Although this 2-port sensor detects only coil current, producing 330mV/A, we use it to characterize and correct amplifier performance, determine B1 strength, and null coil coupling currents. Still, on-coil current sensors are limited without a matching voltage measurement, as true impedances cannot be measured, and on-coil sensors may present practical challenges in routing additional cables from the coil array to receivers. RF Vector Power Sensor A 4-port vector sensor, eg directional coupler, is capable of full voltage, current, power flow, and impedance measurements similar to a one-port network analyzer. Our vector power sensors are slottedline voltage and current transducers, employing transmission line construction designed for low 0.1dB insertion loss and -40dB sensor outputs [6] (Fig 2a). Although a 4-port sensor requires more extensive s-parameter calibration, we can use it to perform precision impedance and power flow measurements (Fig. 4). Scan Impedance and Amplifier Limits Scan impedance, a concept from antenna array theory [7], describes the time-varying impedance modulation seen at each amplifier in an array due to mutually-coupled drive from other elements. Phased-array beam “scanning” is a close corollary to fully-parallel transmit excitation. Measuring scan impedance over the course of PTx playback can be done at low RF power to reveal any moments of significant amp-coil mismatch, allowing prediction of when and where an amp will exceed its voltage/current dynamic range causing the pulse to fail. Alternately, the same data can be used to make the pulse design realizable. This method is relevant even for high-Z amps. Amplifier Impedance Control & Decoupling with Source Absorption RF amplifiers are frequently used at their native uncontrolled output impedance, or with passive isolation methods, e.g. circulators, to induce a 50Ω Zout. However, with the ability to sense load current and voltage, it is no longer necessary to rely on passive Zout manipulation. Using the source absorption theorem [8], we can synthesize arbitrary passive impedances using our amplifier as an active dependent source. For example, a current-controlled voltage source with complex gain Z yields V = I*Z, an active synthesis of Ohm’s Law, the very definition of impedance behavior. Thus by using Cartesian Feedback or VIP, we can elicit high output impedance for coil decoupling even though the open-loop amplifier has 50Ω output impedance. The approach works as long as the amplifier is within its dynamic range. Conclusions The use of RF sensor feedback is key to high-fidelity transmit array performance. Sensors enable iterative predistortion and Cartesian feedback techniques that provide adaptive amplifier linearization, transient corrections, and active output impedance control for array decoupling. Furthermore, vector RF sensors and in-system measurement of coil impedance makes possible significant new patient and equipment safety features. References [1] U. Katsher et al, MRM, 49, 144. [2]Y Zhu, MRM 51, 775, 2004 2003. [3] P Stang et al, 17th ISMRM, 395, 2009. [4] D Hoult et al, JMR 171:64,2006. [5] Zanchi et al, 17th ISMRM, 398, 2009. [6] P Stang et al, 17th ISMRM, 3024, 2009. [7] J.Allen & B.Diamond, Tech. Report 424, DTIC #AD-648153, 1966. [8] A.Sedra, K.Smith, Microelectronic Circuits, 1987. Grant support: NIH R01EB008108, R21EB007715, R01EB005407. Figure 1: Vector Iterative Predistortion (VIP) uses coil sensors to detect virtually all amplifier non-ideality (left) and compensates to produce a high quality 4-ch 2x accelerated excitation with excellent profile and spurious excitation at the noise floor (right).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vector Iterative Pre-Distortion: An Auto-calibration Method for Transmit Arrays

INTRODUCTION: Transmit arrays hold growing promise for MRI by enabling improved safety, RF homogeneity, selectivity, and pulse acceleration. Yet achieving good performance with complex Transmit-SENSE pulses [1] requires Tx array channels to be characterized, closely calibrated, and decoupled. To address these needs, we propose Vector Iterative Pre-distortion (VIP), a multichannel iterative corr...

متن کامل

B1 Mapping and Parallel Excitation using Vector Decoupling

Introduction: Parallel RF excitation is a novel technology that can significantly accelerate multidimensional selective excitation, improve RF homogeneity and reduce SAR. High-fidelity excitation requires accurate knowledge of the transmit array B1 sensitivity profiles and a linear RF transmit system. We present an approach using vector decoupling [1] to facilitate measurement of the B1 sensiti...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

RF PA Linearization: Open-loop Digital Predistortion Using Cartesian Feedback for Adaptive PA Characterization

This work combines the advantages of two different RF power amplifier (PA) linearization techniques: digital predistortion (DPD) and Cartesian feedback (CFB). Cartesian feedback, an extension of classical continuoustime feedback, is limited by the bandwidth of its loop transfer function; this bandwidth, in turn, puts an upper limit on the bandwidth of the data input. However, this limitation gi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009