Incorporation of motion information for tumour volume definition in PET

نویسندگان

  • Mathieu Hatt
  • Amandine Le Maitre
  • Daphné Wallach
  • Hadi Fayad
  • Dimitris Visvikis
چکیده

The interest of PET complementary information for the delineation of the target volume in radiotherapy of lung cancer is increasing. However, respiratory motion requires the determination of a functional internal target volume (ITV) on PET images for which several strategies have been proposed. The purpose of this study was the comparison of these strategies for taking into account respiratory motion and deriving the ITV: 1) adding fixed margins to the volume defined on a single binned image, 2) segmenting a motion averaged image, and 3) considering the union of volumes delineated on binned frames. For this third strategy, binned frames were either non-corrected for motion, or corrected using two different methods: elastic registration or super resolution. The strategies' performances were assessed on realistic simulated datasets combining the NCAT phantom with a PET Philips GEMINI scanner model in GATE, and containing various configurations of tumor to background contrast, with both regular and irregular respiratory motion (with a range of motion amplitudes). The obtained ITVs' sensitivity (SE) and positive predictive value (PVE) with respect to the known true ITV were significantly higher (from 0.8 to 0.95) than all other techniques when using binned frames corrected for motion, independently of motion regularity, amplitude, or tumor to background contrast. Although the absolute difference was small and not always significant, images corrected using super resolution led to systematically better results than using elastic registration. The worst results were obtained when using the motion averaged image for sensitivity (around 0.5-0.6) and using the margins added to a single frame for PPV (0.6-0.7) respectively. The best strategy to account for breathing motion for tumor ITV delineation in radiotherapy planning is to rely on the use of the union of volumes delineated on super resolution-corrected binned images. 1. Introduction Computed tomography (CT) is routinely used for delineating gross target volumes (GTV) and organs at risk (OAR) in radiotherapy treatment planning (RTP) of lung cancer. However, the high sensitivity and specificity of 18 F-FDG Positron Emission Tomography (PET) for diagnosis and staging, as well as the widespread availability of combined PET/CT scanners, led to numerous studies investigating the potential of PET/CT for target volume delineation. Use of PET/CT images has been shown to reduce intra and inter observer variability in target volume delineation [Ashamalla 2005, Steenbakkers 2006, van Baardwijk 2007], as well as significantly modifying GTVs [Walter 1999, Bradley 2004]. Moreover, PET imaging allows characterizing tracer uptake heterogeneities than …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

Positron emission tomography for target volume definition in the treatment of non-small cell lung cancer.

The additional benefit of positron emission tomography (PET) in the initial staging of non-small cell lung cancer (NSCLC) has generated interest in 18F-fluorodeoxyglucose (FDG) PET as a means of defining the extent of primary lung tumour for radiotherapy treatment planning (RTP). A review of published data suggests that PET results in a reduction in the CT-derived GTV for NSCLC primary target v...

متن کامل

In vivo imaging of cellular proliferation in renal cell carcinoma using 18F-fluorothymidine PET

Objective(s): The ability to measure cellular proliferation non-invasively in renal cell carcinoma may allow prediction of tumour aggressiveness and response to therapy. The aim of this study was to evaluate the uptake of 18Ffluorothymidine (FLT) PET in renal cell carcinoma (RCC), and to compare this to 18F-fluorodeoxyglucose (FDG), and to an immunohistochemical measure of cellular proliferatio...

متن کامل

Comparing PET metabolic parameters with clinicopathological factors in predicting onset of early recurrence in recently diagnosed hepatocellular carcinoma

Introduction: Early recurrence of hepatocellular carcinoma (HCC) is a major risk factor affecting survival even after hepatectomy. Many clinical, biochemical parameters and pathological grading like fibrosis 1 index have been used for risk stratifying HCC. However not many studies have combined all of them. It is therefore important to risk stratify HCC especially with newer PE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012