Simulation of normal cardiovascular system and severe aortic stenosis using equivalent electronic model.

نویسندگان

  • Mehmet Korürek
  • Mustafa Yıldız
  • Ayhan Yüksel
چکیده

OBJECTIVE In this study, we have designed an analog circuit model of the cardiovascular system that is able to simulate normal condition and cardiovascular diseases, such as mitral stenosis, aortic stenosis, and hypertension. Especially we focused on severe aortic stenosis, because it is one of the causes of sudden death in asymptomatic patients. In this study, we aim to investigate the simulation of the cardiovascular system using an electronic circuit model under normal and especially severe aortic valve stenosis conditions. METHODS The Westkessel model including RLC pi-segments is chosen in order to simulate both systemic and pulmonary circulation. The left and right heart is represented by trapezoidal shape stiffnesses. Aortic capacitance and aortic valve characteristics are chosen nonlinear. Severe aortic stenosis is implemented by changing the value of the serial resistance to the aortic valve. MATLAB software program is used for the model implementation. RESULTS The results for normal conditions of the given electrical model are similar to the normal cardiovascular physiology. As a result of simulation, a remarkable increase of the left ventricle systolic blood pressure and aortic mean pressure gradient, and decrease of aortic systolic blood pressure are observed in severe aortic valve stenosis. CONCLUSION In conclusion, our model is effective and available for simulating normal cardiac conditions and cardiovascular diseases, especially severe aortic stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling the Circle of Willis Using Electrical Analogy Method under both Normal and Pathological Circumstances

Background and objective: The circle of Willis (COW) supports adequate blood supply to the brain. The cardiovascular system, in the current study, is modeled using an equivalent electronic system focusing on the COW.Method: In our previous study we used 42 compartments to model whole car- diovascular system. In the current study, nevertheless, we extended our model by using 63 compartments to m...

متن کامل

Simulation of Cardiovascular Diseases Using Electronic Circuits

We have developed an electronic circuit to simulate the behavior of the cardiovascular system under normal or pathological conditions. The current, voltage, charge, resistance and capacitance of the circuit correspond to flow, blood pressure, volume, resistance and capacitance of the simulated cardiovascular system, respectively. We have implemented a circuit with two ventricles separated from ...

متن کامل

Analog Simulation of Aortic Stenosis

In cardiovascular physiology mathematical and analog simulations are well known (Beneken, 1965; Defares et al.; 1963, Grodins; 1959; Kordaš et al., 1968; Milhorn, 1966; Osborn,1967;). However, in analog modelling physical electrical models have been replaced by computer analysis of electronic analog circuitry. Then they have been applied to various physiological systems (Bošnjak & Kordaš, 2002;...

متن کامل

Simulation of Exercise-Induced Syncope in a Heart Model with Severe Aortic Valve Stenosis

Severe aortic valve stenosis (AVS) can cause an exercise-induced reflex syncope (RS). The precise mechanism of this syncope is not known. The changes in hemodynamics are variable, including arrhythmias and myocardial ischemia, and one of the few consistent changes is a sudden fall in systemic and pulmonary arterial pressures (suggesting a reduced vascular resistance) followed by a decline in he...

متن کامل

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 2010