Simultaneous Measurement of Intracellular pH and K+ or NO3- in Barley Root Cells Using Triple-Barreled, Ion-Selective Microelectrodes.

نویسندگان

  • D. J. Walker
  • S. J. Smith
  • A. J. Miller
چکیده

The manufacture and use of triple-barreled microelectrodes, which are capable of simultaneous in vivo measurement of intracellular pH and the activities of K+ or NO3- and cell membrane potential (Em), are described. Scanning electron micrographs showed that the three tips were aligned and that the overall tip diameter was approximately 0.8 [mu]m. When filled with 100 mM KCl, all three barrels simultaneously reported identical transmembrane potentials, showing that all three tips were located in the same subcellular compartment. Intracellular estimates of Em in barley (Hordeum vulgare L. cv Klaxon) root epidermal cells obtained with these triple-barreled microelectrodes were indistinguishable from those obtained using single- or double-barreled microelectrodes. Measurements made with triple-barreled K+ and pH-selective microelectrodes in root cells of 7-d-old barley plants grown in a nutrient solution containing 0.5 mM K+ yielded cytosolic and vacuolar populations having mean K+ activity values of 71.3 and 68.7 mM, respectively. The associated mean pH values ([plus or minus]SE) were 7.26 [plus or minus] 0.06 (cytosol) and 5.18 [plus or minus] 0.08 (vacuole). Analysis of whole-tissue digests confirmed the microelectrode measurements. Measurements made using triple-barreled pH- and nitrate-selective microelectrodes confirmed earlier double-barreled measurements of pH and nitrate in barley root epidermal cells growing in 10 mM nitrate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue.

Electrical activity in the brain is accompanied by significant ion fluxes across membranes, resulting in complex changes in the extracellular concentration of all major ions. As these ion shifts bear significant functional consequences, their quantitative determination is often required to understand the function and dysfunction of neural networks under physiological and pathophysiological cond...

متن کامل

Nitrate interference with potassium-selective microelectrodes

tions of K+, and triple-barrelled microelectrodes measuring K pH and membrane potential m have provided Initial attempts to measure K+ activity (a K ) in vacuoles a major advance towards this goal ( Walker et al., 1995, of barley leaf epidermal cells using triple-barrelled K+1996). The incorporation of a pH-sensing barrel allows selective microelectrodes gave values that were only unequivocal a...

متن کامل

Single-cell measurements of the contributions of cytosolic Na(+) and K(+) to salt tolerance.

Ion concentrations in the roots of two barley (Hordeum vulgare) varieties that differed in NaCl tolerance were compared after exposure to NaCl. Triple-barreled H(+)-, K(+)-, and Na(+)-selective microelectrodes were used to measure cytosolic activities of the three ions after 5 and 8 d of NaCl stress. In both varieties of barley, it was only possible to record successfully from root cortical cel...

متن کامل

Measurement of intracellular pH of skeletal muscle with pH-sensitive glass microelectrodes.

We used three methods to examine the relationship among intracellular pH, transmembrane potential, and extracellular pH. Single-barreled electrodes permitted the determination of resting potential and intracellular pH with a minimum of cellular injury. Double-barreled electrodes, which incorporated a reference as well as a pH-sensitive electrode in a single tip, facilitated the direct measureme...

متن کامل

Physicochemical properties of a liquid ion exchanger microelectrode and its application to biological fluids.

Double-barreled potassium or chloride ion-selective microelectrodes were constructed using a liquid ion exchanger. Technical details of the fabrication of double-barreled microelectrodes, having a PD sensor as one barrel and an ionic sensor as the other, are described. The sensitivity of K+ or CI- ion-selective microelectrodes exhibited an approximately Nernstian response over a temperature ran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Plant physiology

دوره 108 2  شماره 

صفحات  -

تاریخ انتشار 1995