Evaluation of iris color stability in ocular prosthesis.
نویسندگان
چکیده
UNLABELLED Accurate iris reproduction in the fabrication of ocular prosthesis in order to match the remaining eye is a key factor to mask the loss and achieve an esthetic outcome for anophthalmic patients. This study evaluated the stability of acrylic paints used for replicating iris color in ocular prostheses by the analysis of two factors: the temperature of the acrylic resin polymerization cycle during prosthesis fabrication and the incidence of sun light, which is the main photodegrading agent undermining the longevity of ocular prostheses. An accelerated aging assay was used for both analyses. Specimens simulating the prosthetic iris in the colors blue, yellow, black, brown and green were fabricated, and were submitted to a colorimetric reading before and after undergoing the thermal conditions of acrylic resin polymerization. Next, the specimens were submitted to an artificial accelerated aging assay with ultraviolet radiation A and weekly colorimetric readings during a 3-week period. The color change (Delta E*) values for the four specimens painted with the same color paint were averaged and the resulting values were considered for statistical analysis. Levine's test and Student's t-test were used to analyze the influence of the temperature of the polymerization cycle during prosthesis fabrication on the color stability of each acrylic resin paint. Friedman's test for three dependent samples was used for analysis of color photodegradation as function of time. Significance level was set at 0.05 for all analyses. It was observed that, after the action of the temperature of the polymerization cycle, alteration above clinically acceptable level of Delta E*> 3.3 was observed only for the yellow color. After the accelerated aging assay, there were statistically significant differences (p<0.05) as a function of time in the green, brown, black and blue colors. Changes were clinically acceptable for the brown and black colors; slightly above the clinically acceptable limit for the green color; and significantly high and impracticable from a clinical standpoint for the blue color. There was no statistically significant differences (p>0.05) for the yellow color, which presented color change only a little above the clinically acceptable limit. IN CONCLUSION 1. Only the yellow color presented alterations above the clinically acceptable levels after the polymerization cycle; 2. After accelerated aging, there was no changes in the yellow color above the clinically acceptable levels; 3. For the green color, degradation was significant and slightly above the clinically acceptable levels; 4. The black, brown and blue colors presented significant alterations as function of time; the alterations of the brown and black colors were within acceptable clinical levels, while the blue color presented a more accentuated degradation over time.
منابع مشابه
The Prosthetic Rehabilitation of Phthisis Bulbi Using Semi-customized Ocular Prosthesis: A Technical Note
Mutilation in the facial region may significantly affect the self-image and personality of individuals. Prosthetic rehabilitation of facial defects could increase the quality of life, thereby encouraging the patients to build up their self-confidence to return to normal social life. Acceptable cosmetic results are often obtained through facial prosthesis. Recovery after the loss of an eye requi...
متن کاملEvaluation of the color stability of two techniques for reproducing artificial irides after microwave polymerization
UNLABELLED The use of ocular prostheses for ophthalmic patients aims to rebuild facial aesthetics and provide an artificial substitute to the visual organ. Natural intemperate conditions promote discoloration of artificial irides and many studies have attempted to produce irides with greater chromatic paint durability using different paint materials. OBJECTIVES The present study evaluated the...
متن کاملChromatic changes to artificial irises produced using different techniques.
Ocular prostheses are important determinants of their users' aesthetic recovery and self-esteem. Because of use, ocular prostheses longevity is strongly affected by instability of the iris color due to polymerization. The goal of this study is to examine how the color of the artificial iris button is affected by different techniques of artificial wear and by the application of varnish following...
متن کاملEvaluation of Knowledge and Practice of Yazd General Practitioners about Shade Selection of Fixed Dental Prosthesis in 2019
Introduction: The color matching of dental restorations is effective in the beauty of the smile and a dentist should be familiar with the subject of color and light to make a beautiful and natural prosthesis. The aim of this study was to investigate the knowledge and practice of general dentists in Yazd City about the choice of fixed prosthesis color in 2019. Methods: This was a descriptive-an...
متن کاملColor alteration of the paint used for iris painting in ocular prostheses.
The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of equal size, of scleral white colored acrylic resin, with the painting interposed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2008