Ultrafiltration for the treatment of congestion: a window into the lung for a better caress to the heart.
نویسندگان
چکیده
A significant proportion of patients treated for acute decompensated heart failure (ADHF) suffer from worsening renal function, which is often associated with medical therapy resistance and poor outcome. In this setting, haemofiltration has been used for more than 30 years, despite inconclusive evidence for its advantages. In the last decade, a major technological advances have made available a new technique, ultrafiltration, which works at lower blood flow rates and requires only a venous access. As in a first proof-of-concept study (EUPHORIA), ultrafiltration proved to be efficacious in fluid removal in ADHF patients; this treatment was further investigated in randomized controlled trials. The RAPID-CHF trial demonstrated that ultrafiltration was more effective than medical therapy in fluid removal, even though it did not provide a greater weight loss. The UNLOAD trial thereafter showed a greater weight loss with ultrafiltration compared with diuretic therapy at 48 h after admission and a lower readmission rate at 90 days. Based on these results, the AHA/ACC and ESC guidelines consider ultrafiltration as a reasonable approach in ADHF patients with unresolved congestion notwithstanding optimal medical therapy and/or hyponatremia. However, the recently published CARRESS-HF trial would appear to challenge these recommendations as it failed to demonstrate an advantage of ultrafiltration compared with medical therapy, based on the finding of subtle clinically irrelevant changes in renal function between treatments. This review focused on the current evidence supporting the use of ultrafiltration and on a critical appraisal of the recently published CARRESS-HF trial.
منابع مشابه
Energy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملPneumonia infection by Morganella morganii in a male alpaca
After sudden death with a history of about two weeks ruminal tympany, a 3-year-old, male alpaca from Huantaiqi Zoo, Chongqing, China was presented to the Animal Diseases Rapid Diagnosis Center, Southwest University, Chongqing, China for diagnosis of the death causes. At necropsy, the primary pathological lesions were found in the lung. A pronounced hemorrhage with topical congestion and lobular...
متن کاملEvaluation the Toxicopathological Lesions of Berberis Vulgaris Using a Chicken Embryonic Model
Toxicopathological effects of herbs have always been a major concern. There is scant information available about the toxicopathological effects of barberry in the fetus. Since the embryogenesis in chicken is similar to human beings, the objective of this study is to evaluate the lesions of the various dosages of Berberis vulgaris using a chicken embryonic model. Fertile chicken eggs were divide...
متن کاملDosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer
Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...
متن کاملEvaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms
Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 29 7 شماره
صفحات -
تاریخ انتشار 2014