False aneurysm following modified Blalock-Taussig shunt.
نویسندگان
چکیده
A nine month old infant with life threatening tracheal compression due to a Blalock-Taussig shunt aneurysm is described. Successful surgical management is discussed.
منابع مشابه
Complications of modified Blalock-Taussig shunts mimicking pulmonary disease.
The modified Blalock-Taussig shunt is commonly performed as early palliation in cyanotic congenital heart disease. To highlight unusual diagnostic problems in such patients, two cases are reported in whom shunt complications were initially diagnosed as lobar pneumonia and tuberculosis, respectively. The children, an 8 month old boy and a 3 year old boy, had false aneurysm secondary to infection...
متن کاملBlalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...
متن کاملPseudoaneurysm following modified Blalock Taussig shunt.
The modified Blalock-Taussig (BT) shunt is a common palliative procedure for congenital cyanotic heart disease (CHD) with diminished pulmonary blood flow(1). In developing countries, definitive surgery usually gets delayed due to limited resources and expertise(2). Children with cyanotic CHD and BT shunt often present to the pediatrician resulting in some of the complications of BT shunt being ...
متن کاملBalloon dilatation of a stenosed modified (polytetrafluoroethylene) Blalock-Taussig shunt.
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence of proximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months l...
متن کاملModified Blalock-Taussig shunt versus ductal stenting for palliation of cardiac lesions with inadequate pulmonary blood flow.
OBJECTIVE The modified Blalock-Taussig shunt is the most commonly used palliative procedure for infants with ductal-dependent pulmonary circulation. Recently, catheter-based stenting of the ductus arteriosus has been used by some centers to avoid surgical shunt placement. We evaluated the durability and safety of ductal stenting as an alternative to the modified Blalock-Taussig shunt. METHODS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pediatric cardiology
دوره 23 2 شماره
صفحات -
تاریخ انتشار 1994