Study on Fault Current of DFIG during Slight Fault Condition
نویسندگان
چکیده
In order to ensure the safety of DFIG when severe fault happens, crowbar protection is adopted. But during slight fault condition, the crowbar protection will not trip, and the DFIG is still excited by AC-DCAC converter. In this condition, operation characteristics of the converter have large influence on the fault current characteristics of DFIG. By theoretical analysis and digital simulation, the fault current characteristics of DFIG during slight voltage dips are studied. And the influence of controller parameters of converter on the fault current characteristics is analyzed emphatically. It builds a basis for the construction of relay protection which is suitable for the power gird with accession of DFIG.
منابع مشابه
Variable Speed Wind Turbine DFIG Back to Back Converters Open-Circuit Fault Diagnosis by Using of Combiniation Signal-Based and Model-Based Methodes
Condition monitoring (CM) and Fault Detection (FD) of wind turbine lead to increase in reliability and availability of turbine. IGBT open circuit of wind turbine converter will bring about depletion in output current of converter and as a result, reduction in production of wind turbine power. In this research, back to back converter IGBT open - gate fault for wind turbine based on DFIG is detec...
متن کاملRETRACTED! Transient stability enhancement of DFIG based 10 MW wind farm by using of new inductive bridge type fault current limiter
RETRACTED
متن کاملFault Behavior of Wind Turbines
Synchronous generators have always been the dominant generation type in the grid. This fact affected both planning and operation of power systems. With the fast increase of wind power share in the grid in the last decade, the situation is changing. In some countries wind power represents already a consistent amount of the total generation. Wind turbines can be classified as non-synchronous gene...
متن کاملProtection of DFIG wind turbine using fuzzy logic control
Double Fed Induction Generator; Crowbar protection; ANFIS; Fuzzy logic; Fault current and voltages Abstract In the last 15 years, Double Fed Induction Generator (DFIG) had been widely used as a wind turbine generator, due its various advantages especially low generation cost so it becomes the most important and promising sources of renewable energy. This work focuses on studying of using DFIG a...
متن کاملبهبود قابلیت گذر از خطای منابع تولید پراکنده مبتنی بر اینورتر با استفاده از محدود کنندهی جریان خطا
By increasing the penetration level of the inverter-based distributed generations (IBDGs) in power system, their fault ride through capability has become one of the essential issues of the new grid codes. This paper proposes a novel method to limit inverter fault currents which are used in DGs. To achieve FRT, interface-inverter operates as a controlled voltage source during normal operation as...
متن کامل