Hplc Detectors: a Brief Review

نویسنده

  • Michael Swartz
چکیده

& In an HPLC system the detector is the component responsible for turning a physical or chemical attribute into a measureable signal corresponding to concentration or identity. In the early days of HPLC, detection was often carried out by collecting fractions and analyzing them off-line. It wasn’t until the 1940’s and 1950’s that the first online detectors for HPLC were introduced. Certainly an improvement over off-line approaches, sensitivity was an issue. The search for more sensitive universal detectors for HPLC led researchers to adapt GC detectors for use in HPLC, but the removal of the HPLC mobile phase originally limited applicability. However, in the 1960s the first ultraviolet detector for HPLC was introduced, and subsequent improvements in design led to better sensitivity and improvements such as variable wavelength and diode array detectors. While a truly universal HPLC detector with GC=FID levels of sensitivity is still elusive, many different types of detectors have been developed that have been very successful for a wide variety of general or specific HPLC applications. To assist in choosing the proper HPLC detector for a given application, this review describes the principles and attributes of many of the common HPLC detectors in use today, and compares and contrasts the advantages and disadvantages of the various detectors discussed where appropriate. For additional detail on the HPLC detectors addressed here, the reader is encouraged to consult the references in each section along with additional general reviews.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HPLC Separation of Anthraquinones from Rhubarbs

Rheum species are medicinally important herbs, posses several type of biological activities due to the presence of anthraquinone derivatives. Several HPLC methods have been used for sepeatation of anthraquinone of Rheum Species. In most cases anthraquinones were separated using C18 column as a stationary phase, acetonitrile, water and methanol with or without acid as mobile phase at 1.0 ml/min ...

متن کامل

Review of recent advances in non 3D dosimeters

This review covers papers from the previous two years not being represented at this conference. Optically stimulated luminescence detectors, diamond detectors and radiochromic film are the major topics. An effort to link these papers to 3D dosimetry is included in this brief report. An overall theme of linear, water equivalent response is seen throughout the topics included.

متن کامل

Performance of the Fluorescence Detectors of the Pierre Auger

Fluorescence detectors of the Pierre Auger Observatory have been operating in a stable manner since January 2004. After a brief review of the physical characteristics of the detectors, the associated atmospheric monitoring, the calibration infrastructure and the detector aperture, we will describe the steps required for the reconstruction of fluorescence event data, with emphasis on the shower ...

متن کامل

Spherical Gravitational Wave Detectors

Resonant bar gravitational wave detectors have improved greatly over the last 40 years but are currently completely outperformed by laser interferometer detectors. Spherical detector configuration has several advantages over conventional bar detectors and can be considered as the next generation of resonant gravitational wave antenna. In this report, I will give a brief introduction to gravitat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010