Effect of Adjunct Balloon Dilation after Long Everolimus-eluting Stent Deployment on Major Adverse Cardiac Events

نویسندگان

  • Sung-Jin Hong
  • Chul-Min Ahn
  • Dong-Ho Shin
  • Jung-Sun Kim
  • Byeong-Keuk Kim
  • Young-Guk Ko
  • Donghoon Choi
  • Ae-Young Her
  • Yong Hoon Kim
  • Yangsoo Jang
  • Myeong-Ki Hong
چکیده

BACKGROUND AND OBJECTIVES The effectiveness of adjunct balloon dilation after drug-eluting stent (DES) deployment has not been sufficiently evaluated. We evaluated whether adjunct balloon dilation was associated with a reduction in major adverse cardiac events (MACEs) after long everolimus-eluting stents (EESs) implantation. SUBJECTS AND METHODS Drawing from 2 randomized trials, a total of 1,672 patients treated with long EES were analyzed. Of 1,672 patients, 1,061 patients (64%) received post-stent adjunct balloon dilation. MACE, defined as a composite of cardiac death, myocardial infarction, and target-lesion revascularization (TLR), was compared between patients who received post-stent adjunct balloon dilation and patients who did not in 595 propensity score-matched pairs. RESULTS For the matched population, MACE occurred in 29 patients (4.9%) who received adjunct balloon dilation and in 29 patients (4.9%) who did not (hazard ratio [HR], 1.01; 95% confidence interval [CI], 0.60-1.69; p=0.972). However, significant interactions were observed among the subgroups for clinical presentation and vessel size. Adjunct balloon dilation was more favored within the subset of patients with stable angina vs. the subset of patients with acute coronary syndrome (p for interaction=0.037), and within the subset of lesions with small vessel diameter (reference vessel diameter [RVD] <3 mm) vs. the subset of lesions with larger vessel diameter (RVD ≥3 mm; p for interaction=0.027). CONCLUSION Adjunct balloon dilation was not associated with MACE reduction at 1 year among patients requiring long EES implantation. However, post-stent adjunct balloon dilation may be necessary for patients requiring long EES implantation who present with stable angina or for lesions with small vessel diameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Three-year follow-up of patients with bifurcation lesions treated with sirolimus- or everolimus-eluting stents: SEAside and CORpal cooperative study.

INTRODUCTION AND OBJECTIVES To compare the 3-year incidence of major events in patients with bifurcation lesions treated with provisional sirolimus-eluting stents vs everolimus-eluting stents. METHODS A pooled analysis of 2 prospective randomized trials with similar methodology (SEAside and CORpal) was performed. In these trials, 443 patients with bifurcation lesions were randomly assigned to...

متن کامل

Multiple Stent Fractures After Everolimus-Eluting Stent Implantation Causing Acute Myocardial Infarction: A Case Report.

Stent fracture is an uncommon complication of drug-eluting stent implantation, but it has a clinical significance because of its potential association with adverse cardiac events such as in-stent restenosis, target lesion revascularization, and stent thrombosis. Multiple stent fractures account for a small proportion, but they may lead to more serious complications. Newer generation drug-elutin...

متن کامل

Optical coherence tomography.

Case presentation: A 56-year-old man presented to the hospital with chest pain and a non–ST-segment elevation myocardial infarction. Thrombotic plaque rupture in the left anterior descending coronary artery was treated with an everolimus-eluting stent. After stent deployment, angiography demonstrated the presence of a hazy opacity at the distal edge of the stent, and there was concern about a p...

متن کامل

Impact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials.

OBJECTIVES The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES). BACKGROUND Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention. METHODS Patient-level data were pooled from t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2017