Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints.

نویسندگان

  • Jonathan J Elsner
  • Yoav Mezape
  • Keren Hakshur
  • Maoz Shemesh
  • Eran Linder-Ganz
  • Avi Shterling
  • Noam Eliaz
چکیده

There is growing interest in the use of compliant materials as an alternative to hard bearing materials such as polyethylene, metal and ceramics in artificial joints. Cushion form bearings based on polycarbonate-urethane (PCU) mimic the natural synovial joint more closely by promoting fluid-film lubrication. In the current study, we used a physiological simulator to evaluate the wear characteristics of a compliant PCU acetabular buffer, coupled against a cobalt-chrome femoral head. The wear rate was evaluated over 8 million cycles gravimetrically, as well as by wear particle isolation using filtration and bio-ferrography (BF). The gravimetric and BF methods showed a wear rate of 9.9-12.5mg per million cycles, whereas filtration resulted in a lower wear rate of 5.8mg per million cycles. Bio-ferrography was proven to be an effective method for the determination of wear characteristics of the PCU acetabular buffer. Specifically, it was found to be more sensitive towards the detection of wear particles compared to the conventional filtration method, and less prone to environmental fluctuations than the gravimetric method. PCU demonstrated a low particle generation rate (1-5×10⁶ particles per million cycles), with the majority (96.6%) of wear particle mass lying above the biologically active range, 0.2-10μm. Thus, PCU offers a substantial advantage over traditional bearing materials, not only in its low wear rate, but also in its osteolytic potential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: a 20 million cycles wear simulation.

Soft bearing materials that aim to reproduce the tribological function of the natural joint are gaining popularity as an alternative concept to conventional hard bearing materials in the hip and knee. However, it has not been proven so far that an elastic cushion bearing can be sufficiently durable as a long term (∼20 years) articulating joint prosthesis. The use of new bearing materials should...

متن کامل

Study of the Polycarbonate-Urethane/Metal Contact in Different Positions during Gait Cycle

Nowadays, a growing number of young and more active patients receive hip replacement. More strenuous activities in such patients involve higher friction and wear rates, with friction on the bearing surface being crucial to ensure arthroplasty survival in the long term. Over the last years, the polycarbonate-urethane has offered a feasible alternative to conventional bearings. A finite element m...

متن کامل

Predictive wear modeling of the articulating metal-on-metal hip replacements.

The lubrication regime in which artificial hip joints operate adds complexity to the prediction of wear, as the joint operates in both the full fluid film regime-specifically the elastohydrodynamic lubrication (EHL) regime-and the mixed or boundary lubrication regimes, where contact between the bearing surfaces results in wear. In this work, a wear model is developed which considers lubrication...

متن کامل

Wear Loss Evaluation of Silicon Nitride-Hexagonal Boron Nitride Composite using Taguchi Method

Biomaterials in body environment are expected to work satisfactorily, where the pH value of body fluid varies from 1 to 9. Friction, wear, and lubrication of artificial joints are an important consideration to optimise the performance of these man-made joints to improve its function and life. The first metal-on-metal (CoCr-CoCr) total hip replacement (THR) was unsatisfactory because of high fri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta biomaterialia

دوره 6 12  شماره 

صفحات  -

تاریخ انتشار 2010