Initial results from an in-vacuum undulator in the NSLS X-ray ring.
نویسندگان
چکیده
A short-period in-vacuum undulator for the NSLS X-ray Ring has been developed in a collaboration between SPring-8 and the NSLS, and has achieved its project design goals during commissioning studies. The device is called IVUN (in-vacuum undulator) and employs magnet arrays (31 periods, with an 11 mm period) developed at SPring-8, while the requisite vacuum chamber and mechanical systems were developed at the NSLS. At a magnet gap of 3.3 mm, IVUN produces 4.6 keV radiation in the fundamental, with useful photon fluxes in both the second and third harmonics. The magnet gap is adjustable between 2 and 10 mm. A brief overview of IVUN is presented, together with initial commissioning results: the dependence of electron-beam lifetime and bremsstrahlung on magnet gap, and the output radiation spectrum.
منابع مشابه
Small-gap Undulator Experiment on the Nsls X-ray Ring"
We report results of an on-going experiment being carried out in the X13 straight section of the NSLS X-ray Ring which explores the limits of the operation of small-gap undulators. In particular, we discuss measurements of stored electron beam lifetime as a function of the vertical aperture presented by a 4-jaw scraper or a variable-aperture vacuum vessel. At an electron beam current of 300 mA ...
متن کاملNsls In-vacuum Undulators and Mini-beta Straights
We review the work carried out in the X13 R&D Straight Section of the NSLS X-Ray Ring on small gap in-vacuum undulators (IVUNs). Then we discuss: (1) plans to replace the pure permanent magnet undulator in X13 by a hybrid design providing stronger magnetic fields, enhancing the tunability of the device; (2) plans to install hybrid IVUNs in the two RF straights of the X-Ray Ring, increasing the ...
متن کاملDevelopment of an in-vacuum minipole undulator.
An in-vacuum minipole (short-period) insertion device has been developed in a collaboration between SPring-8 and the National Synchrotron Light Source (NSLS). The magnetic arrays were constructed by SPring-8 and were installed in a chamber with mechanical parts in the X-ray ring (E = 2.584 GeV) at the NSLS in May 1997. The device is made of permanent magnets with 30.5 periods and a period lengt...
متن کاملMechanical Design of NSLS Mini-gap Undulator (MGU)
The mechanical design considerations are discussed with respect to the currently installed X-13 and future X-29 MGU. Comparisons to the previous 2 generations of variable small-gap undulator evolution in the NSLS X-ray ring are made and design improvements noted. The design requirements and mechanical difficulties for holding, positioning and driving the magnetic arrays are explored. Structural...
متن کاملCoherent Radiation for X-Ray Imaging-The Soft X-Ray Undulator and the X1A Beamline at the NSLS.
An undulator-based beamline was built and commissioned at the National Synchrotron Light Source to provide tunable coherent radiation in the 200-800 eV range. The low emittance of the storage ring means that the undulator source has high brightness so that a large flux of coherent x rays is delivered to experimental stations. The beamline uses a horizontally dispersing bichromator that allows t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 5 Pt 3 شماره
صفحات -
تاریخ انتشار 1998