Reproducibility of high-resolution optical coherence tomography in multiple sclerosis.

نویسندگان

  • Stephanie B Syc
  • Christina V Warner
  • Girish S Hiremath
  • Sheena K Farrell
  • John N Ratchford
  • Amy Conger
  • Teresa Frohman
  • Gary Cutter
  • Laura J Balcer
  • Elliot M Frohman
  • Peter A Calabresi
چکیده

Optical coherence tomography (OCT) is a non-invasive method to quantify neurodegeneration as an outcome in multiple sclerosis clinical trials; however, no data exist on Cirrus spectral domain optical coherence tomography (SD-OCT) reproducibility in patients with multiple sclerosis. The objective of this study was to determine the protocol for achieving optimal inter-visit, inter-rater, and intra-rater reproducibility for studies performed on healthy controls and multiple sclerosis patients utilizing novel high-definition SD-OCT. This is a prospective study of inter-visit, inter-rater, and intra-rater reproducibility in multiple sclerosis patients (n = 58) and healthy controls (n = 32) on Cirrus-HD SD-OCT. Excellent reproducibility of average and quadrantic retinal nerve fiber layer (RNFL) thickness values, average macular thickness (AMT), and total macular volume (TMV) [measured by intraclass correlation coefficient (ICC)] was found for inter-visit (healthy controls: mean RNFL = 0.97, quadrant range = 0.92-0.97, AMT = 0.97, TMV = 0.92), inter-rater (MS: mean RNFL = 0.97, quadrant = 0.94-0.98, AMT = 0.99, TMV = 0.96; healthy controls: mean RNFL = 0.97, quadrant = 0.94-0.97, AMT = 0.98, TMV = 0.99), and intra-rater (MS patients: mean RNFL = 0.99, quadrant = 0.83-0.99, AMT = 0.97, TMV = 0.98) reproducibility. The reproducibility of retinal measures derived by Cirrus HD-OCT, especially quadrantic values, is excellent. Specific procedures for OCT acquisition and analysis of retinal imaging metrics using SD-OCT technology may improve the application of this novel technology in multiple sclerosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Coherence Tomography and Corpus Callosum Index in Cognitive Assessment of Multiple Sclerosis Patients

Background: Multiple Sclerosis (MS) is a neurodegenerative disease of central nervous system. Different approaches have been developed to study MS progression and cognitive dysfunction as the major symptom of the disease. The current study compared Optical Coherence Tomography (OCT) and Corpus Callosum Index (CCI) for the early evaluation of cognitive dysfunction in MS patients.  Objectives: T...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography

Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Multiple sclerosis

دوره 16 7  شماره 

صفحات  -

تاریخ انتشار 2010