Overestimation of the LVEF by quantitative gated SPECT in simulated left ventricles.

نویسندگان

  • P V Ford
  • S N Chatziioannou
  • W H Moore
  • R D Dhekne
چکیده

UNLABELLED During routine myocardial perfusion imaging, a common observation is that patients with normal cardiac function and small hearts, in particular small women, have higher left ventricular ejection fractions (LVEFs), as measured by quantitative gated SPECT (QGS) software, than anticipated, often markedly so. The goal of this project was to determine if the QGS LVEF varies with the change in end-diastolic left ventricular volume (EDV) and in particular to verify that the clinically observed phenomenon of falsely elevated QGS LVEF in patients with small hearts is actually occurring. METHODS A series of mathematically defined left ventricles (LVs) was produced by varying the EDV and targeted LVEF (tLVEF). These were created using concentric hemiellipsoids with nine different EDVs. The tLVEF was varied from 15% to 75% by 5% increments for a total of 13 different ejection fractions. These datasets were then smoothed, creating a total of 234 sets. The smoothed and unsmoothed images were then processed using QGS software. The LVEFs and EDVs were recorded. RESULTS For lower LVEFs the agreement between the QGS LVEF and the tLVEF is good. A marked overestimation occurs when the EDVs are low and the ejection fractions are in the higher range. This effect is greater in the smoothed images. CONCLUSION An artifactual increase in the LVEF can occur when measurements are made with the QGS software. These data argue against using QGS LVEF for monitoring the LVEF in patients with small hearts. Our data imply that a mildly decreased LVEF may still appear to be in the normal range when measured by QGS software.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Impact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI

Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...

متن کامل

The prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease

Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2001