The Impact of Pinless Navigation in Conventionally Aligned Total Knee Arthroplasty

نویسندگان

  • P Koenen
  • M M Schneider
  • T R Pfeiffer
  • B Bouillon
  • H Bäthis
چکیده

Background Restoration of the mechanical axis is a main objective in total knee replacement (TKR). Aim of this study was to analyse the verification tool of a pinless navigation system in conventional TKR (cTKR). Methods In a prospective study, 147 TKR were performed by conventional technique. Using the "pinless verification" mode of a smartphone based navigation system, the cutting block position and final resection plane for distal femur and proximal tibial resection were measured. If necessary, the block position or resection level were optimized, corrections were protocolled. Postoperatively, standardized radiographs were performed. Results In 65.3%, intraoperative measurements changed the surgical procedure (corrections: 20.4% femoral, 25.9% tibial, 19% both). The additional time for surgery compared to cTKR averaged 6 minutes (79 ± 15 versus 73 ± 17 minutes). Using navigation data, the final femoral and tibial axes were in 93% within a range of ±2°. A mean difference of 1.4° and 1.6° could be shown between the final measurement of the navigation system and the postoperative mLDFA and mMPTA. Conclusion Intraoperative pinless navigation has impact on the surgical procedure in the majority of cTKR. It represents a less time-consuming tool to improve implant position while maintaining the routine of conventional technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical outcomes of computer-assisted total knee arthroplasty using pinless navigation.

This study aims to evaluate the 2-year post-operative clinical outcomes of patients undergoing total knee arthroplasty (TKA) with computer-assisted surgery (CAS) using the pinless BrainLAB® VectorVision® Knee 2.5 Navigation System versus standard CAS. A retrospective case-control study of 200 patients who underwent TKA with CAS from 2008 to 2012 was conducted. Patients in the pinless arm underw...

متن کامل

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Cadaveric Results of an Accelerometer Based Pinless Navigation System for Tibial Resection in Total Knee Arthroplasty

Arthroplasty +Nam, D; Dy, CJ; Cross, MB; Lee, JH; Kim, S; Mayman, DJ Hospital for Special Surgery, New York, New York Senior Author: [email protected] PURPOSE: Total knee arthroplasty (TKA) has proven to be tremendously successful in the management of knee arthritis, but concerns still exist regarding component positioning, as a recent meta-analysis demonstrated 31.8% of TKAs performed with conve...

متن کامل

Erratum to: Improving outcomes in total knee arthroplasty—do navigation or customized implants have a role?

Modern total knee arthroplasty is effective at treating the pain and disability associated with osteoarthritis. The number of total knee replacements done in the USA continues to increase. Despite the great care taken during all of these procedures, some patients remain dissatisfied with their outcome. While this dissatisfaction is likely multifactorial, malalignment of the prosthetic component...

متن کامل

Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty.

BACKGROUND Whether total knee arthroplasty with use of computer-assisted surgical navigation can improve the limb and component alignment is a matter of debate. We hypothesized that total knee arthroplasty with use of computer-assisted surgical navigation is superior to conventional total knee arthroplasty with regard to the precision of implant positioning. METHODS Sequential simultaneous bi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2018  شماره 

صفحات  -

تاریخ انتشار 2018