Sensitivity of an immunomagnetic-separation-based test for detecting Escherichia coli O26 in bovine feces.

نویسندگان

  • L M Hall
  • J Evans
  • A W Smith
  • M C Pearce
  • H I Knight
  • G Foster
  • J C Low
  • G J Gunn
چکیده

The sensitivity of a test for cattle shedding Escherichia coli serogroup O26 was estimated using several fecal pats artificially inoculated at a range of concentrations with different E. coli O26 strains. The test involves the enrichment of fecal microflora in buffered peptone water, the selective concentration of E. coli O26 using antibody-coated immunomagnetic-separation beads, the identification of E. coli colonies on Chromocult tryptone bile X-glucuronide agar, and confirmation of the serogroup with E. coli serogroup O26-specific antisera using slide agglutination. The effective dose of E. coli O26 for an 80% test sensitivity (ED(80)) was 1.0 x 10(4) CFU g(-1) feces (95% confidence interval, 4.7 x 10(3) to 2.4 x 10(4)). Differences in test sensitivity between different E. coli O26 strains and fecal pats were also observed. Individual estimates of ED(80) for each strain and fecal pat combination ranged from 4.2 x 10(2) to 4.8 x 10(5) CFU g(-1). These results suggest that the test is useful for identifying individuals shedding a large number of E. coli O26 organisms or, if an appropriate number of individuals in a herd are sampled, for identifying affected herds. The study also provides a benchmark estimate of sensitivity that can be used to compare alternative tests for E. coli O26 and a methodological approach that can be applied to tests for other pathogenic members of the Enterobacteriaceae and other sample types.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Escherichia coli serogroups O26, O103, O111 and O145 from bovine faeces using immunomagnetic separation and PCR/DNA probe techniques.

AIMS The aim of this study was to isolate Escherichia coli O26, O103, O111 and O145 from 745 samples of bovine faeces using (i) immunomagnetic separation (IMS) beads coated with antibodies to lipopolysaccharide, and slide agglutination (SA) tests and (ii) PCR and DNA probes for the detection of the Verocytotoxin (VT) genes. METHODS AND RESULTS IMS-SA tests detected 132 isolates of presumptive...

متن کامل

Immunomagnetic separation of Escherichia coli O26, O111 and O157 from vegetables.

AIMS Raw fruits and vegetables have been increasingly associated with human infections caused by Shiga toxin-producing Escherichia coli. This study evaluates the isolation and detection of E. coli O26, O111 and O157 from vegetable samples using immunomagnetic particles. METHODS AND RESULTS Standard cultivation and immunomagnetic separation (IMS) procedures were compared. It was found that imm...

متن کامل

Evaluation of the Reveal and SafePath rapid Escherichia coli O157 detection tests for use on bovine feces and carcasses.

The Reveal (Neogen Corp., Lansing, Mich.) and SafePath (SafePath Laboratories LLC, St. Paul, Minn.) tests were evaluated for their performance as beef fecal and beef carcass Escherichia coli O157:H7 monitoring tests. Agreement between these tests and a reference test system was determined using naturally contaminated bovine feces and beef carcasses. The reference system utilized immunomagnetic ...

متن کامل

Chromogenic agar medium for detection and isolation of Escherichia coli serogroups O26, O45, O103, O111, O121, and O145 from fresh beef and cattle feces.

Non-O157 Shiga toxin-producing Escherichia coli (STEC) strains are clinically important foodborne pathogens. Unlike E. coli O157:H7, these foodborne pathogens have no unique biochemical characteristics to readily distinguish them from other E. coli strains growing on plating media. In this study, a chromogenic agar medium was developed in order to differentiate among non-O157 STEC strains of s...

متن کامل

Improvement of immunomagnetic separation for Escherichia coli O157:H7 detection by the PickPen magnetic particle separation device.

Conventional immunomagnetic separation (IMS) procedures, which use an external magnetic source to capture magnetic particles against the side of a test tube, are labor-intensive and can have poor sensitivity for the target organism because of high background microflora that is not effectively washed away during the IMS process. This report compares the conventional IMS procedure to a new IMS pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 72 11  شماره 

صفحات  -

تاریخ انتشار 2006