Chronic transverse sternal fracture. Role of CT scan and repair by an alternative use of the Synthes-Titanium Sternal Fixation System.

نویسندگان

  • F Monaco
  • S Lentini
  • F Tancredi
  • M Savasta
  • O Perrone
  • M Monaco
  • R Gaeta
  • B Mondello
  • M Barone
چکیده

Chest wall fractures, including injuries of the sternum, usually heal spontaneously without specific treatment. However sometimes, they need surgical treatment. To treat these patients the selection criteria often are subjective in spite of many surgical devices for sternal osteosynthesis are available nowadays. One of the most recent device is the Synthes-Titanium Sternal Fixing System, usually used to treat post-sternotomy dehiscence. We describe the case of a 67-year-old man with previous history of chest trauma presenting to our institution with chronic transverse sternal fracture. We describe the pre-operative study, stressing the particular role of the CT scan and a surgical approach by an alternative use of the Synthes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sternal reconstruction with titanium plates in complicated sternal dehiscence.

OBJECTIVE Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. The use of titanium plates is a promising approach for sternal reconstruction. METHODS Titanium plate fixation was used in 15 patients (67+/-5.9 years, 171+/-8.2 cm, 93.6+/-14.9 kg, body mass index 32+/-5 kg/m(2)) with unstable thorax after failed attempts of sternal c...

متن کامل

The laparoscopically harvested omental flap and transverse plate fixation for sternal reconstruction in complicated sternal wound infection after cardiac surgery

Methods Between 2010 and 2011, 6 patients with type IV deep sternal wound infection underwent a sternal reconstruction with a laparoscopically harvested omental flap and transverse plate fixation. The median age of the cohort (1 female and 5 males), was 72.5 years (range: 4978 years). In 5 patients, a bilateral internal thoracic artery had been used. Considerable preoperative risk factors were ...

متن کامل

Sternal reentry in a patient with previous deep sternal wound infection managed with horizontal titanium plate fixation

Redo open-heart surgery and sternal reentry in patients with previous deep sternal wound infection (DSWI) and absence of sternal integrity can be a delicate and morbid task due the lack of a dissection plane between the heart and the surrounding soft tissues. Delayed sternal reconstruction and osteosynthesis with horizontal titanium plating fixation (Synthes) following vacuum assisted therapy (...

متن کامل

Use of titanium plate fixation system in late sternal dehiscence repair

Sternal instability with mediastinitis is a very serious complication after median sternotomy. Sternal dehiscence repair together with debridement of the infected tissue is the mainstay of therapy where various modalities are employed. Here, we report the use of titanium plate for sternum stabilization in a patient with sternal dehiscence and superficial wound infection.

متن کامل

[Ectopic spleen. Urgent or elective surgery?].

Transverse sternal nonunion, repair and revision: a case report and review of the literature. J Trauma. 2009;66:1485–8. 3. Potaris K, Gakidis J, Mihos P, Voutsinas V, Deligeorgis A, Petsinis V. Management of sternal fractures: 239 cases. Asian Cardiovasc Thorac Ann. 2002;10:145–9. 4. Morgan A. Treatment of chronic nonunion of a sternal fracture with bone morphogenetic protein. Ann Thorac Surg. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Il Giornale di chirurgia

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2009