Factors affecting selectivity in ion chromatography.
نویسنده
چکیده
Methods for separation of ions by ion-exchange, ion-pair, and zwitterion ion chromatography share at least one common thread--the induced formation of a cation-anion pair in the stationary phase. Selectivity can be defined as the relative ability of sample ions to form such a pair. Examples are given in anion-exchange chromatography to show the effect of variations in the geometry, bulkiness and polarity of the resin cation on selectivity. The type of resin matrix, the hydrophobic nature of the resin surface and the degree of solvation also affect chromatographic behavior. The selectivity series observed in ion chromatography seems to be best explained by the interplay of two components: electrostatic attraction (ES) and the enforced-pairing (EP) that is brought about by hydrophobic attraction and by water-enforced ion pairing. Selectivity in ion-pair chromatography (IPC) and in zwitterion ion chromatography (ZIC) is affected by both the mobile phase cation and anion. This leads to elution orders for anions that are different from conventional ion-exchange chromatography (IC) of anions where cations are excluded from the stationary phase and have little effect on a separation. The elution order of anions in ZIC is similar to that in IC except for small anions of 2-charge, which are retained more weakly in ZIC. A unique advantage of ZIC is that sample ions can be eluted as ion pairs with pure water as the eluent and a conductivity detector. The mechanism for separation of anions on a zwitterionic stationary phase has been a subject for considerable debate. The available facts point strongly to a partitioning mechanism or a mixed mechanism in which partitioning is dominant with a weaker ion-exchange component.
منابع مشابه
Some factors affecting separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection.
Some factors influencing the separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection were investigated. These factors include eluent concentration, column temperature, and detection waveform. The selectivity changes in weakly retained amino acids are slight with changing sodium hydroxide eluent concentration. When s...
متن کاملIon Size Exclusion Chromatohtaphy on Hypercrosslinked Polystyrene Sorbents as a Green Technology of Separating Mineral Elecyrolites
Inamuddin, A. Mohammad (eds.), Green Chromatographic Techniques, DOI 10.1007/978-94-007-7735-4_2, © Springer Science+Business Media Dordrecht 2014 V. Davankov () · M. Tsyurupa · Z. Blinnikova Nesmeyanov-Institute of Organo-Element Compounds, Russian Academy of Sciences, 119991 Moscow, Russia e-mail: [email protected] Abstract The review considers a new preparative method of separating concent...
متن کاملتهیه الکترود یونگزین بر پایه پلی وینیل کلرید برای اندازهگیری دیمتیل آمینو اتیلکلراید هیدروکلراید
Dimethyl amino ethyl chloride hydrochloride (DMC) is a primary material of fuel of dimethyl amino ethyl azide (DMAZ) that is a good alternative for hydrazine derivatives in the aerospace industry. Some amount of unreacted DMC remains in the wastewater in production processes of DMAZ (95% wt.) that due to toxicity and corrosion effect of DMC, determination of this compound in DMAZ waste is ine...
متن کاملRapid determination of germanium and tin by ion chromatography
A method was established for the simultaneous determination of germanium and tin in one run by ion chromatography. Using a selected eluent, Ge and Sn were separated on a bifunctional ion-exchange column, followed by a postcolumn chromogenic reaction and spectrophotometric detection at 520 nm. The whole procedure was completed within 5 min with high sensitivity and selectivity at the low-/zg/1 l...
متن کاملHigh-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1085 1 شماره
صفحات -
تاریخ انتشار 2005