Evaluation and optimization of a commercial enzyme linked immunosorbent assay for detection of Chlamydophila pneumoniae IgA antibodies

نویسندگان

  • Olfa Frikha-Gargouri
  • Radhouane Gdoura
  • Abir Znazen
  • Nozha Ben Arab
  • Jalel Gargouri
  • Mounir Ben Jemaa
  • Adnene Hammami
چکیده

BACKGROUND Serologic diagnosis of Chlamydophila pneumoniae (Cpn) infection routinely involves assays for the presence of IgG and IgM antibodies to Cpn. Although IgA antibodies to Cpn have been found to be of interest in the diagnosis of chronic infections, their significance in serological diagnosis remains unclear. The microimmunofluorescence (MIF) test is the current method for the measurement of Cpn antibodies. While commercial enzyme linked immunosorbent assays (ELISA) have been developed, they have not been fully validated. We therefore evaluated and optimized a commercial ELISA kit, the SeroCP IgA test, for the detection of Cpn IgA antibodies. METHODS Serum samples from 94 patients with anti-Cpn IgG titers > or = 256 (study group) and from 100 healthy blood donors (control group) were tested for the presence of IgA antibodies to Cpn, using our in-house MIF test and the SeroCP IgA test. Two graph receiver operating characteristic (TG-ROC) curves were created to optimize the cut off given by the manufacturer. RESULTS The MIF and SeroCP IgA tests detected Cpn IgA antibodies in 72% and 89%, respectively, of sera from the study group, and in 9% and 35%, respectively, of sera from the control group. Using the MIF test as the reference method and the cut-off value of the ELISA test specified by the manufacturer for seropositivity and negativity, the two tests correlated in 76% of the samples, with an agreement of K = 0.54. When we applied the optimized cut-off value using TG-ROC analysis, 1.65, we observed better concordance (86%) and agreement (0.72) between the MIF and SeroCP IgA tests. CONCLUSION Use of TG-ROC analysis may help standardize and optimize ELISAs, which are simpler, more objective and less time consuming than the MIF test. Standardization and optimization of commercial ELISA kits may result in better performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation of an indirect enzyme-linked immunosorbent assay by purified gp51SU for detection of antibodies to bovine leukemia virus

The objective of this study was to compare an indirect ELISA, based on a purified 60 kDa envelope glycoprotein (gp51SU), with a Pourquire indirect ELISA for the detection of antibodies to the bovine leukemia virus. For conducting this research, 340 serum samples were collected from two different breeds of cows (Sarabi and Holestin) in different herds. Commercial ELISA revealed positive results ...

متن کامل

Designing an enzyme-linked immunosorbent assay for detection of anti-penicillin antibodies levels in various species of animals in Khuzestan province, Iran

The penicillin allergy is being increasingly recognized as a significant public health problem. Immunological responses to penicillin and other beta-lactam antibiotics are classified as immediate and non-immediate responses. This research aimed to develop an enzyme-linked immunosorbent assay (ELISA) for the detection of the reactive antibody value against penicillin in various species of animals...

متن کامل

Standardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.

An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...

متن کامل

Enzyme-Linked Immunosorbent Assay of Progesterone in Serum Using Penicillinase as Label

An enzyme-linked immunosorbent assay (ELISA) for progesterone measurement in serum or plasma samples using penicillinase as label enzyme is reported. A C3 and C11 derivatives of progesterone were prepared and conjugated to bovin serum albumin (BSA). Polyclonal antibody against these two immunogens were prepared in New Zealand white rabbits. Purified Ig fractions of antibodies were immobilized o...

متن کامل

ENZYME-LINKED IMMUNOSORBENT ASSAY OF NEOPTERIN USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay for neopterin using penicillinase as marker enzyme is reported here by polyclonal antibodies against neopterin conjugated to bovine serum albumin which were raised in rabbits. Immunoglobulin fractions were purified and coated on wells of microtiter plates. A chain heterology was introduced in neopterin derivative and conjugated to penicillinase. The assa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Infectious Diseases

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008