Reduction of Endorectal Surface Coil Artifact in 1H Spectroscopic MRI of Prostate Cancer
نویسندگان
چکیده
Introduction H MR spectroscopic imaging (MRSI) has become an important tool for the evaluation and staging of prostate cancer patients since changes in the peak areas of the choline, polyamines, and citrate resonances have been correlated with the presence and aggressiveness of prostate cancer [1]. However, the inhomogeneous reception profile of the endorectal coil reduces metabolite peak areas with distance from the coil, confounding the interpretation of the prostate MRSI data. The diminished coil sensitivity in the anterior aspect of the prostate can cause central gland tumors to be missed on H MRSI. Typically the choline/citrate or (choline+creatine) / citrate metabolite peak area ratios are used to identify cancer and to address the inhomogeneous reception profile [2,3]. However, these ratios can be quite variable, particularly when citrate levels are low, as in cancer and in the central gland. The elevation of choline levels alone may be a more robust indicator of cancer presence and cancer aggressiveness [3]. To overcome the problems with metabolite ratios and provide the ability to monitor individual metabolites, we have developed a semi-automatic procedure which normalizes the MRSI data to the analytic reception profile of the endorectal coil [4]. The aim of this study was to 1) evaluate the improvement in spectral homogeneity in phantoms and patients using this coil correction algorithm and, 2) in an additional group of patients with central gland tumors, determine the tumor choline versus healthy peripheral zone choline before and after coil correction to illustrate the potential of this method to facilitate central gland tumor detection. Methods The endorectal receiver coil's sensitivity map was modeled based upon the Biot-Savart Law [4]. The coil's position and orientation were manually identified on the axial and sagittal T2-weighted images. The field map was rotated, translated, and sinc-resampled to the resolution of the MRSI data. The spectral array was then normalized by the resampled coil profile. Numerical integration of suppressed water, choline, creatine, and citrate was performed before and after coil correction using the known frequency positions of each of these peaks [5]. Three uniform phantoms and 18 prostate cancer patients were scanned at 3T using PRESS selected, 3D (12x16x16) MRSI with TR/TE=1300/85 and 0.16cc resolution. In the 3 phantom studies, the average coefficients of variation cv = σ/μ for integrals of the water, choline, creatine, and citrate peaks for all non-VSS-suppressed voxels in the selected volume were calculated before and after correction. For the patients, cv was only calculated for water, due to large biological variability in metabolites. In three patients, the choline peak areas were analyzed in anterior prostatic regions that were suspicious of tumor by lowered apparent diffusion coefficient (ADC) [6]. ROIs were drawn around the regions of ADC abnormality and regions of healthy peripheral zone. The ratio of the mean choline integral value in the tumor region to that in the healthy region was then calculated for both the corrected and uncorrected choline maps. Results All peaks from the phantom scans showed increased uniformity with lower cv values postcorrection (see Table 1). Figure 1 shows this improvement in the spectral data facilitating the visualization of spectra especially anteriorly. Figure 2 graphically shows this improvement as increased flatness in the axial profile of the phantom citrate integrals post correction. Uniformity of water also increased in the 18 patients (cv pre =1.0±0.2 to cv post = 0.7±0.1, p<0.05). As shown in Figure 3, correction of spectra for the reception profile of the endorectal coil improved detection of the anterior tumor based on elevated choline. The patient in Figure 3 had a biopsy proven anterior central gland tumor which was not clear on T2-weighted images (Figure 3a), the (choline+creatine)/citrate map (Figure 3b), or the uncorrected choline map (Figure 3c), but was clear on the corrected choline map (Figure 3d) and on the apparent diffusion coefficient (ADC) map (Figure 3e). For the three cases with central gland tumors, the ratio of choline integrals within the abnormal regions to the integrals in the healthy peripheral zone increased from 1.0 ± 0.2 (μ ± σ), or no difference, for uncorrected spectra to 2.0 ± 0.9 (μ ± σ) for corrected spectra. Discussion This correction algorithm not only decreases variability in metabolite levels, it also shows promise in facilitating cancer detection and, ultimately, in facilitating automated spectral classification. The absolute peak areas of coilcorrected data could yield automatically produced maps that are more sensitive and more specific to pathology than uncorrected maps or metabolite ratio maps, which become quite variable when the divisor metabolite has low signal to noise. The elevated choline voxels indicating a central gland tumor in the post-correction choline map in Figure 3d) are clearly more specific than the pre-correction map (Figure 3c). The evaluation of absolute peak area maps generated in this fashion may enable more objective and automatic spectral interpretation. References [1] Scheidler, et al. Radiology 1999; 213: 473-80 [2] Kurhanewicz, et al. Radiology 1996; 795-805 [3] Kurhanewicz J, et al. Neoplasia 2000; 2(1-2) 166-169 [4] Moyher SE, et al. J of Magnetic Resonance Imaging. 1995 5: 139-144. [5] Nelson S and Brown T. J of Magnetic Resonance Imaging. 1987; 84:95-109. [6] Reinsberg SA, et al. AJR 2007; 188:91-98. Funding: NIH: ROI CA079980, CA111291, CA59897, ACS MRSG0508701CCE Table 1: Increase in phantom metabolite area uniformity with MRSI coil correction. Peak cv before* cv after* Improvement Water 0.7 ± 0.1** 0.4 ± 0.1** 39 ± 8%
منابع مشابه
MR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils
Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...
متن کاملComparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer
PURPOSE Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil ...
متن کامل[Characterization of prostate cancer, benign prostatic hyperplasia and normal prostates using endorectal 1H magnetic resonance spectroscopy].
BACKGROUND We evaluate the usefulness of 1H endorectal resonance spectroscopy to characterize prostate pathology. METHODS With an endorectal surface coil we have studied 20 individuals with normal (1), benign hyperplastic (9) and malignant (10) prostates. RESULTS The major findings of our studies were that the patients with cancer have a significantly lower citrate-to-choline ratio (cit/cho...
متن کاملMonte Carlo-based noise compensation in coil intensity corrected endorectal MRI
BACKGROUND Prostate cancer is one of the most common forms of cancer found in males making early diagnosis important. Magnetic resonance imaging (MRI) has been useful in visualizing and localizing tumor candidates and with the use of endorectal coils (ERC), the signal-to-noise ratio (SNR) can be improved. The coils introduce intensity inhomogeneities and the surface coil intensity correction bu...
متن کاملPhased-array MRI of canine prostate using endorectal and endourethral coils.
A four-channel phased array consisting of one surface coil, two endorectal coils, and one flexible endourethral loop coil was designed for MRI of the canine prostate. The endorectal coils provide high signal in the posterior region of the prostate, while the endourethral and surface coils are sensitive to the central and anterior regions of the prostate. Gel phantom experiments indicate that th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008