Towards Low Energy Atrial Defibrillation
نویسندگان
چکیده
A wireless powered implantable atrial defibrillator consisting of a battery driven hand-held radio frequency (RF) power transmitter (ex vivo) and a passive (battery free) implantable power receiver (in vivo) that enables measurement of the intracardiac impedance (ICI) during internal atrial defibrillation is reported. The architecture is designed to operate in two modes: Cardiac sense mode (power-up, measure the impedance of the cardiac substrate and communicate data to the ex vivo power transmitter) and cardiac shock mode (delivery of a synchronised very low tilt rectilinear electrical shock waveform). An initial prototype was implemented and tested. In low-power (sense) mode, >5 W was delivered across a 2.5 cm air-skin gap to facilitate measurement of the impedance of the cardiac substrate. In high-power (shock) mode, >180 W (delivered as a 12 ms monophasic very-low-tilt-rectilinear (M-VLTR) or as a 12 ms biphasic very-low-tilt-rectilinear (B-VLTR) chronosymmetric (6ms/6ms) amplitude asymmetric (negative phase at 50% magnitude) shock was reliably and repeatedly delivered across the same interface; with >47% DC-to-DC (direct current to direct current) power transfer efficiency at a switching frequency of 185 kHz achieved. In an initial trial of the RF architecture developed, 30 patients with AF were randomised to therapy with an RF generated M-VLTR or B-VLTR shock using a step-up voltage protocol (50-300 V). Mean energy for successful cardioversion was 8.51 J ± 3.16 J. Subsequent analysis revealed that all patients who cardioverted exhibited a significant decrease in ICI between the first and third shocks (5.00 Ω (SD(σ) = 1.62 Ω), p < 0.01) while spectral analysis across frequency also revealed a significant variation in the impedance-amplitude-spectrum-area (IAMSA) within the same patient group (|∆(IAMSAS1-IAMSAS3)[1 Hz - 20 kHz] = 20.82 Ω-Hz (SD(σ) = 10.77 Ω-Hz), p < 0.01); both trends being absent in all patients that failed to cardiovert. Efficient transcutaneous power transfer and sensing of ICI during cardioversion are evidenced as key to the advancement of low-energy atrial defibrillation.
منابع مشابه
Low-energy multistage atrial defibrillation therapy terminates atrial fibrillation with less energy than a single shock.
BACKGROUND Implantable device therapy of atrial fibrillation (AF) is limited by pain from high-energy shocks. We developed a low-energy multistage defibrillation therapy and tested it in a canine model of AF. METHODS AND RESULTS AF was induced by burst pacing during vagus nerve stimulation. Our novel defibrillation therapy consisted of 3 stages: stage (ST) 1 (1-4 low-energy biphasic [BP] shoc...
متن کاملAtrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.
OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...
متن کاملLow-energy cardioversion with epicardial wire electrodes: new treatment of atrial fibrillation after open heart surgery.
BACKGROUND Atrial fibrillation (AF) is the most common arrhythmia after open heart surgery. Traditional treatment with a range of antiarrhythmic drugs and electrical cardioversion is associated with considerable side effects. The aim of this study was to examine the feasibility and efficacy of low-energy atrial defibrillation with temporary epicardial defibrillation wire electrodes. METHODS A...
متن کاملFavorable effects of flecainide in transvenous internal cardioversion of atrial fibrillation.
OBJECTIVES The aim of the study was to evaluate the effects of intravenous (IV) flecainide on defibrillation energy requirements in patients treated with low-energy internal atrial cardioversion. BACKGROUND Internal cardioversion of atrial fibrillation is becoming a more widely accepted therapy for acute episode termination and for implantable atrial defibrillators. METHODS Twenty-four pati...
متن کاملLow-energy atrial defibrillation: a promising new technique.
Temporary epicardial wire electrodes placed during open heart surgery for potential diagnostic and/or therapeutic use in patients in the immediate postoperative period have been used safely and effectively as part of standard care for a long time. We have also known that synchronized delivery of a low-energy DC shock for cardioversion of atrial fibrillation is very effective. With the presentat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2015