The effects of positive end-expiratory pressure during active compression decompression cardiopulmonary resuscitation with the inspiratory threshold valve.

نویسندگان

  • W G Voelckel
  • K G Lurie
  • T Zielinski
  • S McKnite
  • P Plaisance
  • V Wenzel
  • K H Lindner
چکیده

UNLABELLED The use of an inspiratory impedance threshold valve (ITV) during active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) improves perfusion pressures, and vital organ blood flow. We evaluated the effects of positive end-expiratory pressure (PEEP) on gas exchange, and coronary perfusion pressure gradients during ACD + ITV CPR in a porcine cardiac arrest model. All animals received pure oxygen intermittent positive pressure ventilation (IPPV) at a 5:1 compression-ventilation ratio during ACD + ITV CPR. After 8 min, pigs were randomized to further IPPV alone (n = 8), or IPPV with increasing levels of PEEP (n = 8) of 2.5, 5.0, 7.5, and 10 cm H(2)O for 4 consecutive min each, respectively. Mean +/- SEM arterial oxygen partial pressure decreased in the IPPV group from 150 +/- 30 at baseline after 8 min of CPR to 110 +/- 25 torr at 24 min, but increased in the PEEP group from 115 +/- 15 to 170 +/- 25 torr with increasing levels of PEEP (P <0.02 for comparisons within groups). Mean +/- SEM diastolic aortic minus diastolic left ventricular pressure gradient was significantly (P < 0.001) higher after the administration of PEEP (24 +/- 0 vs 17 +/- 1 mm Hg with 5 cm H(2)O of PEEP, and 26 +/- 0 vs 17 +/- 1 mm Hg with 10 cm H(2)O of PEEP), whereas the diastolic aortic minus right atrial pressure gradient (coronary perfusion pressure) was comparable between groups. Furthermore, systolic aortic pressures were significantly (P < 0.05) higher with 10 cm H(2)O of PEEP when compared with IPPV alone (68 +/- 0 vs 59 +/- 2 mm Hg). In conclusion, when CPR was performed with devices designed to improve venous return to the chest, increasing PEEP levels improved oxygenation. Moreover, PEEP significantly increased the diastolic aortic minus left ventricular gradient and did not affect the decompression phase aortic minus right atrial pressure gradient. These data suggest that PEEP reduces alveolar collapse during ACD + ITV CPR, thus leading to an increase in indirect myocardial compression. IMPLICATIONS Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation improves perfusion pressures, and vital organ blood flow during cardiac arrest. Increasing levels of positive end-expiratory pressure during performance of active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve improves oxygenation, and increases the diastolic aortic-left ventricular pressure gradient and systolic arterial blood pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of a model lung system to assess the effects of an inspiratory impedance threshold valve on the relationship between active decompression and intra-thoracic pressure.

Use of an inspiratory impedance valve has recently been shown to increase the efficacy of standard and active compression-decompression cardiopulmonary resuscitation. We evaluated the effects of a prototypic impedance valve on the relationship between the active decompression and intra-thoracic pressure using a mechanical model lung system. Intermittent impedance to inspiratory flow of respirat...

متن کامل

Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.

Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...

متن کامل

Use of an inspiratory impedance threshold device on a facemask and endotracheal tube to reduce intrathoracic pressures during the decompression phase of active compression-decompression cardiopulmonary resuscitation.

INTRODUCTION Use of an inspiratory impedance threshold device (ITD) significantly increases coronary perfusion pressures and survival in patients ventilated with an endotracheal tube (ETT) during active compression-decompression cardiopulmonary resuscitation. We tested the hypothesis that the ITD could lower intratracheal pressures when attached to either a facemask or ETT. METHODS An active ...

متن کامل

Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.

OBJECTIVE Assess a prototype inspiratory impedance threshold valve (ITV) designed to enhance vital organ circulation during standard and active compression/decompression cardiopulmonary resuscitation (CPR). BACKGROUND The ITV attaches to commonly used airway assist devices and decreases intrathoracic pressure during the decompression (chest recoil) phase of CPR by creating a vacuum within the...

متن کامل

Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest.

BACKGROUND Blood pressure is severely reduced in patients in cardiac arrest receiving standard cardiopulmonary resuscitation (CPR). Although active compression-decompression (ACD) CPR improves acute hemodynamic parameters, arterial pressures remain suboptimal with this technique. We performed ACD CPR in patients with a new inspiratory threshold valve (ITV) to determine whether lowering intratho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 92 4  شماره 

صفحات  -

تاریخ انتشار 2001