EP09-A3: Measurement Procedure Comparison and Bias Estimation Using Patient Samples; Approved Guideline—Third Edition

نویسندگان

  • Jeffrey R. Budd
  • A. Paul Durham
  • Thomas E. Gwise
  • Beimar Iriarte
  • Anders Kallner
  • Kristian Linnet
  • Robert Magari
  • Jeffrey E. Vaks
چکیده

Clinical and Laboratory Standards Institute document EP09-A3—Measurement Procedure Comparison and Bias Estimation Using Patient Samples; Approved Guideline—Third Edition is written for laboratorians and manufacturers. It describes procedures for determining the bias between two measurement procedures, and it identifies factors for consideration when designing and analyzing a measurement procedure comparison experiment using split patient samples. An overview of the measurement procedure comparison experiment includes considerations for both manufacturers and laboratorians. Details on how to create difference and scatter plots for visual inspection of the data are provided. Once the data are characterized, various methods are introduced for quantifying the relationship between two measurement procedures, including bias estimates and regression techniques. The final section contains recommendations for manufacturers’ evaluation of bias and statement format for bias claims. Clinical and Laboratory Standards Institute (CLSI). Measurement Procedure Comparison and Bias Estimation Using Patient Samples; Approved Guideline—Third Edition. CLSI document EP09-A3 (ISBN 1-56238-887-8 [Print]; ISBN 1-56238-888-6 [Electronic]). Clinical and Laboratory Standards Institute, 950 West Valley Road, Suite 2500, Wayne, Pennsylvania 19087 USA, 2013. The Clinical and Laboratory Standards Institute consensus process, which is the mechanism for moving a document through two or more levels of review by the health care community, is an ongoing process. Users should expect revised editions of any given document. Because rapid changes in technology may affect the procedures, methods, and protocols in a standard or guideline, users should replace outdated editions with the current editions of CLSI documents. Current editions are listed in the CLSI catalog and posted on our website at www.clsi.org. If your organization is not a member and would like to become one, and to request a copy of the catalog, contact us at: Telephone: 610.688.0100; Fax: 610.688.0700; E-Mail: [email protected]; Website: www.clsi.org.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Statistical analysis in method comparison studies – Part one

Method comparison is commonly performed by laboratory specialists to assess the comparability of two methods. The quality of method comparison study determines the quality of the results and validity of the conclusions. The key to the successful method comparison is therefore a well-designed and carefully planned experiment. The question to be answered by the method comparison is whether two me...

متن کامل

Resurgence of penicillin-susceptible Staphylococcus aureus at a hospital in New York State, USA.

4 Anderegg TA, Jones RN, Hall G et al. Initial disk diffusion quality control guidelines for tylosin tested against Staphylococcus aureus ATCC 25923 and Streptococcus pneumoniae ATCC 49619. Int J Antimicrob Agents 2003; 21: 594–6. 5 Clinical and Laboratory Standards Institute. Development of In Vitro Susceptibility Testing Criteria and Quality Control Parameters for Veterinary Antimicrobial Age...

متن کامل

EP14-A2 Evaluation of Matrix Effects; Approved Guideline—Second Edition

Clinical and Laboratory Standards Institute (CLSI) document EP14-A2—Evaluation of Matrix Effects; Approved Guideline— Second Edition was developed for manufacturers, regulators, and providers of proficiency testing or external quality assessment programs, although it will be useful to clinical laboratories as well. The document will help users to determine whether matrix effects are the source ...

متن کامل

Green and efficient synthesis of propargylamines via A3 coupling reaction using a copper (II)–thioamide combination

A one pot green three‐component coupling reaction of aldehyde, phenylacetylene, and amine derivatives in the presence of copper (II)–thioamide combination as a novel and efficient heterogeneous catalyst under solvent–free conditions is reported. The catalyst displayed high activity and afforded the corresponding propargylamines in good to high yields. The key to this procedure was the generatio...

متن کامل

Evaluation of Protamine Level in Human Sperm Samples Using Chromomycin A3 and Aniline Blue Staining

Background: Current microscopic experimental methods cannot diagnose DNA damages present in spermatozoa .Therefore, some methods are needed to address the abnormality of the genetic material status on the sperm samples. As reported by many investigators aniline blue staining technique has been used for identifying sperm chromatin condensation. Also, chromomycin A3 is used for evaluation of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013