Two-dimensional approach to fluorescence yield XANES measurement using a silicon drift detector.

نویسندگان

  • Y Tamenori
  • M Morita
  • T Nakamura
چکیده

The objective of this article is to describe the capability of a two-dimensional (2D) approach to X-ray absorption near-edge structure (XANES) measurement by means of a partial fluorescence yield (PFY) method. 2D-XANES measurements were achieved by using a silicon drift detector as an energy-dispersive fluorescence detector. The advantage of this technique is that it allows full surveys of X-ray fluorescence data that are lost in conventional PFY measurements. The availability of a map approach was demonstrated by applying it to XANES measurements in both a diluted (Mn-doped nano-diamond) and a concentrated (MnO crystal) manganese sample. The 2D approach clearly distinguished between the PFY spectra of Mn and O atoms, where absorption edges of both elements are close to each other. Further, the 2D approach extracted an unambiguous PFY spectrum of phosphorus in the XANES measurement of SS304 (P < 0.045 wt%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial Fluorescence Yield XAFS Measurements in Soft X-ray Region Using a Large-Area Silicon Drift Detector

X-ray absorption fine structure (XAFS) spectra in the soft X-ray region are obtained in the electron and fluorescence yield modes, which are sensitive to surface and bulk, respectively. A micro-channel plate (MCP) can be used as the detector for the total fluorescence yield (TFY) method by applying a sufficiently high negative bias to a grid in front of the MCP. However, this method often suffe...

متن کامل

Commissioning of the Silicon Drift Detectors of the ALICE experiment at the LHC

Silicon Drift Detectors (SDD) equip the two central layers of the Inner Tracking System of the ALICE experiment at the LHC. Main results of systematic studies of detector performance including noise, gain, drift speed and charge collection measurements will be reported. 1 ALICE experiment and SDD module Silicon Drift Detectors (SDD) [1] offer two-dimensional position reconstruction with a limit...

متن کامل

X-ray Absorption spectroscopy on copper trace impurities on silicon wafers

Trace metal contamination during wet cleaning processes on silicon wafer surfaces is a detrimental effect that impairs device performance and yield. Determining the chemical state of deposited impurities helps in understanding how silicon surfaces interact with chemical species in cleaning solutions. However, since impurity concentrations of interest to the semiconductor industry are so low, co...

متن کامل

Gated Silicon Drift Detector Fabricated from a Low-Cost Silicon Wafer

Inexpensive high-resolution silicon (Si) X-ray detectors are required for on-site surveys of traces of hazardous elements in food and soil by measuring the energies and counts of X-ray fluorescence photons radially emitted from these elements. Gated silicon drift detectors (GSDDs) are much cheaper to fabricate than commercial silicon drift detectors (SDDs). However, previous GSDDs were fabricat...

متن کامل

Simulation and Fabrication of Gated Silicon Drift X-Ray Detector Operated by Peltier Cooling

A proposed simply structured gated silicon (Si) drift X-ray detector operated using Peltier cooling and only a single high-voltage source is investigated. Because the device structure is much simpler than that of commercial Si drift detectors (SDDs), which require at least two high-voltage sources, the cost of the X-ray detection system can be reduced. The absorption of cadmium X-ray fluorescen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 18 Pt 5  شماره 

صفحات  -

تاریخ انتشار 2011