Characterization of bremsstrahlung radiations for 6 to 18 MeV electron beam from different Z elements: experimental and simulation approach
ثبت نشده
چکیده
This chapter deals with the study of bremsstrahlung spectra for 6 to 18 MeV electron beam from different materials such as low to high Z elements as an e target. The simulation using FLUKA involves the neutron, electron, positron and bremsstrahlung fluence determination at various angles Moreover the thickness of . , e target has varied from thin to thick i.e from 0.1% to 150% of RCSDA. In addition, the reliability of FLUKA simulation was confirmed by calculating the bremsstrahlung spectrum for the setup of experiments performed by other researchers and corresponding validation was done. The data generated in this chapter can be used as a right hand data for the researchers working in the field of medical, nuclear and accelerator physics.
منابع مشابه
An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method
Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...
متن کاملComparing experimental assessment of the peripheral dose outside the applicator in electron beams of ELEKTA with Treatment planning system
Introduction: The use of electrons in the electron therapy to destroy tumoral tissue is dedicated significant contribution of different methods of radiation therapy. Scattered radiation due to exited electrons of the applicator affect the dose out of the field in the patient's normal tissue. The aim of this study is to determine the peripheral dose outside the applicator in the...
متن کاملPhysical characteristics of electron beam from conventional and beam shaper IOERT applicator: A comparison study
Introduction: Intraoperative electron radiation therapy (IOERT) is one of the cancer treatment techniques that delivers high doses to tumor bed during surgery. IOERT can be performed by either conventional LINACs or dedicated IORT accelerators such as LIAC (Light Intraoperative Accelerator). Two types of applicators can be used with LIAC dedicated accelerator including conventi...
متن کاملA Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation
Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...
متن کاملEstimation of bremsstrahlung photon fluence from aluminum by artificial neural network
Background: As bremsstrahlung photon beam fluence is important parameter to be known in a photonuclear reaction experiment as the number of produced particle is strongly depends on photon fluence. Materials and Methods: Photon production yield from different thickness of aluminum target has been estimated using artificial neural network (ANN) model. Target thickness and incoming electr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011