Intra-aortic balloon pumping: effects on left ventricular diastolic function.

نویسندگان

  • Ashraf W Khir
  • Susanna Price
  • Michael Y Henein
  • Kim H Parker
  • John R Pepper
چکیده

OBJECTIVE The intra-aortic balloon pump is the most widely used form of temporary cardiac assist and often utilised in patients before and after cardiac surgery. Several effects of balloon counter-pulsation have been reported previously, but its effect on left ventricular diastolic function has not been thoroughly investigated. The aim of this study is to examine the effect of the intra-aortic balloon pump on left ventricular wall motion and transmitral flow. METHODS We studied 20 patients in the intensive care unit, less than 36 h following cardiac surgery. We recorded left anterior descending coronary artery and transmitral E-wave flow velocities using transesophageal echocardiography pulsed Doppler. We also recorded left ventricular long axis free-wall movement using M-mode. The intra-aortic balloon pump was set to full augmentation and recordings were made at pumping cycles 1:1, 1:2, 1:3, and when the pump was on stand-by, leaving a minimum of 5 min between the pumping modes to allow the return to control conditions. In order to eliminate time effects, the sequence of recording was varied between patients using a 4 by 4 Latin-square. RESULTS The peak diastolic left anterior descending coronary artery and transmitral E-wave flow velocities, and left ventricular free-wall early diastolic lengthening velocity increased significantly with intra-aortic balloon pumping cycles 1:1, 1:2 and 1:3 compared to their value with the pump on stand-by, all P < 0.001. The increase in peak transmitral E-wave flow velocity correlated with the increase in peak left anterior descending coronary artery diastolic flow velocity (r = 0.74, P = 0.02), and with the increase in left ventricular free-wall early diastolic lengthening velocity (r = 0.80, P < 0.001). CONCLUSION Using the intra-aortic balloon pump post-cardiac surgery significantly increases peak diastolic left anterior descending coronary artery flow velocities and left ventricular free-wall early diastolic lengthening velocity, whose increase explains the increase in peak transmitral E-wave velocity. Although coronary flow is epicardial and mitral flow is intracardial, their close relationship suggests an improvement in left ventricular diastolic function with intra-aortic balloon pump.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental hemodynamic studies with a permanent ventricular assist device. The dynamic aortic patch.

M e c h a n i c a l circulatory assistance by means of diastolic pressure augmentation has proved beneficial in the management of left ventricular failure.l-' Intra-aortic phaseshift balloon pumping, a temporary form of this mode of assistance, has proved successful in the treatment of acute left ventricular failure5-' secondary to myocardial infarction. A permanently implanted assist device, t...

متن کامل

Effect of intraaortic balloon pumping on left ventricular function in patients with persistent ST segment elevation after revascularization for acute myocardial infarction.

The purpose of the present study was to assess the impact of intraaortic balloon pumping (IABP) in patients with persistent ST elevation who underwent revascularization within 6 h of their first acute anterior myocardial infarction (AMI). Persistent ST elevation after revascularization was defined as being > or =50% of the initial value on return to the coronary care unit. Twenty-four patients ...

متن کامل

Intra-aortic balloon pumping (IABP) at different levels of experimental acute left ventricular failure.

Effectiveness of intra-aortic balloon pumping (IABP) as a circulatory assist device was experimentally evaluated in eight groups of dogs at various stages in the sequence: coronary occlusion-myocardial infarctiobacute left ventricular failure-coronary shock. When instituted during the period of reversibiiity of myocardial ischemic changes produced by coronary ligation, IABP improved collateral ...

متن کامل

Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption, and coronary blood flow in dogs.

The effect of intra-aortic counterpulsation (IACP) with a balloon upon myocardial oxygen consumption (MVo2), coronaiy blood flow (TCF), and left ventricular performance was studied in 23 anesthetized canine right heart bypass preparations at constant heart rate and cardiac output. In nonhypotensive, nonTCF-limited preparations, IACP produced a fall in left ventricular peak systolic pressure (LV...

متن کامل

The Influence of Combined Intra-aortic Balloon Counterpulsation and Hyperosmotic Mannitol on Regional Myocardial Blood Flow in Ischemic Myocardium in the Dog

We investigated the combined effectiveness of intraaortic ballooon counterpulsation and hyperosmotic mannitol (25%) on regional myocardial blood flow during acute coronary insufficiency. Cardiac output and paced heart rate were held constant in chloraloseanesthetized dogs during right heart bypass. Acute coronary insufficiency was produced by ligation of the proximal left anterior descending co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 24 2  شماره 

صفحات  -