Development of a Robotic Assembly for Analyzing the Instantaneous Axis of Rotation of the Foot Ankle Complex

نویسندگان

  • Kelly N. Salb
  • Daniel M. Wido
  • Thomas E. Stewart
  • Denis J. DiAngelo
چکیده

Ankle instantaneous axis of rotation (IAR) measurements represent a more complete parameter for characterizing joint motion. However, few studies have implemented this measurement to study normal, injured, or pathological foot ankle biomechanics. A novel testing protocol was developed to simulate aspects of in vivo foot ankle mechanics during mid-stance gait in a human cadaveric specimen. A lower leg was mounted in a robotic testing platform with the tibia upright and foot flat on the baseplate. Axial tibia loads (ATLs) were controlled as a function of a vertical ground reaction force (vGRF) set at half body weight (356 N) and a 50% vGRF (178 N) Achilles tendon load. Two specimens were repetitively loaded over 10 degrees of dorsiflexion and 20 degrees of plantar flexion. Platform axes were controlled within 2 microns and 0.008 degrees resulting in ATL measurements within ±2 N of target conditions. Mean ATLs and IAR values were not significantly different between cycles of motion, but IAR values were significantly different between dorsiflexion and plantar flexion. A linear regression analysis showed no significant differences between slopes of plantar flexion paths. The customized robotic platform and advanced testing protocol produced repeatable and accurate measurements of the IAR, useful for assessing foot ankle biomechanics under different loading scenarios and foot conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Foot/Ankle Based on PKM with Force/Torque Sensor for Humanoid Robot

This paper describes the development of a novel humanoid robot foot/ankle based on an orientation Parallel Kinematic Mechanism for intelligent and flexible control. With three identical Universal-Prismatic-Spherical prismatic-actuated limbs and a central Universal-Revolute passive limb, the PKM can perform three degrees of freedom rotation motions. In order to enable the humanoid robot safely t...

متن کامل

Instantaneous centers of rotation in dorsi/plantar flexion movements of posterior-type plastic ankle-foot orthoses.

Hingeless plastic ankle-foot orthoses (PAFOs) achieve ankle motion by flexing about the ankle joint. Instantaneous centers of rotation (ICRs) in dorsi- and plantarflexion movements, used as a measure of PAFO axes of movement, were measured to evaluate their fit to ankle motion. Thirty different PAFOs were fabricated and their stiffness modified in three stages. They were dorsi- and plantarflexe...

متن کامل

The Effectiveness of Two Night Splints on the Range of Motion of Ankle and Foot Complex, Pain, and Quality of Life in People With Plantar Fasciitis: An Exploratory Parallel-Group Study

Objective: Plantar fasciitis is the most common cause of heel pain. The night splints are used to prevent nocturnal contractures happened in the calf muscles and plantar fascia. The objective of this study was to investigate the effects of using tension night splint for calf and plantar fascia on the range of motion of foot and ankle complex, pain severity, and quality of life. Methods: 30 pe...

متن کامل

Efficacy of Different Types of Foot Orthoses on Postural Control in Subjects With Lateral Ankle Sprain: A Systematic Review

Background and Objectives: Lateral ankle sprain is one of the most common injuries to the musculoskeletal system, especially among active people. This injury causes complex complications, such as recurrent sprain because of reduced postural control. Foot orthoses are among the interventions used to improve postural control in this population. This review aims to investigate foot orthoses to imp...

متن کامل

Design and Control of a Wearable Stewart Platform-Type Ankle-Foot Assistive Device

The design and control of an active ankle‐foot rehabilitation orthotic system that was designed as a wearable and portable rehabilitation and walking assistive tool is presented. This device can measure and assist the six degree of freedoms (DOFs) movement of the human ankle joint by using a Stewart platform mechanism, which can adapt to the displacement of the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016