Regeneration performance of liquid desiccant on the surface of a plate-type heat exchanger
نویسندگان
چکیده
Recently, there have been many studies on dehumidifiers with a low flow rate of liquid desiccant, in which a plate-type heat exchanger with internal cooling is adopted. If the low flow rate of a liquid desiccant maintains a thin liquid film on the heat exchanger surface, heat and mass transfer performance would improve, the stability of the liquid film would increase, and there would be no entrainment of desiccant droplets. In this study, we built an experimental apparatus to measure the regeneration performance of a liquid desiccant and investigated the wettability of the liquid desiccant along the vertical surface of a plate-type heat exchanger. Liquid desiccant was applied to the top of plate heat exchangers having different groove gaps, on which we had applied a hydrophilic coating to enhance the wettability of the liquid desiccant. In a visualization test, we found that a plate heat exchanger with a 1.0-mm groove gap resulted in the greatest wettability. As the mass flow rate of the supplied liquid desiccant increases, the wettability of the liquid desiccant is enhanced, and the regeneration rate and mass transfer coefficient can also be enhanced. We developed experimental correlations for the heat and mass transfer performances of the heat exchanger.
منابع مشابه
Development of a Pilot Plant Solar Liquid Desiccant Air Conditioner for the Northern Region of Iran
In a 10-ton capacity pilot plant solar liquid desiccant air conditioner (LDAC) developed, dehumidification of the outside air is achieved through a honeycomb packed-bed heat and mass exchanger, using lithium chloride solution as the desiccant. The dry air obtained from the dehumidification process is evaporative cooled inside a cooling pad and directed into the conditioned space. The dilute sol...
متن کاملExperimental Investigation of a New Enthalpy Exchanger with Low Absorbent Carryover Designed for Liquid Desiccant Dehumidification System
In this paper, the absorbent carryover effect in a designed counter-flow enthalpy exchanger is investigated. In a built prototype of the liquid desiccant dehumidifier, air and the absorbent solution are in contact and flow through a packed multi-channel polymer tower in a counter-flow pattern. To avoid the absorbent carryover, the tower is equipped with an eliminator. Experimental measurements ...
متن کاملAnalysis on Parameters of Regeneration Subsystem in Liquid Desiccant Dehumidification Systems
Along with the widely use in industries and lives, the dehumidification systems have consumed a large amount of energy. Fortunately, the application of liquid desiccant dehumidification system can greatly reduce the consumption of high-grade energy. To improve the advantages of liquid desiccant system compared with the conventional dehumidification system, one of the key measures is to increase...
متن کاملExperimental Investigation on Hydrodynamic and Thermal Performance of a Gas-Liquid Thermosyphon Heat Exchanger in a Pilot Plant
Waste heat recovery is very important, because not only it reduces the expenditure of heat generation, but also it is of high priority in environmental consideration, such as reduction in greenhouse gases. One of the devices is used in waste heat recovery is heat pipe heat exchanger.Anexperimental research has been carried out to investigate the hydrodynamic and thermal performance of a gas...
متن کاملThe Effect of Geometrical Characteristics of Desiccant Wheel on its Performance
Desiccant wheels are widely used in buildings to control humidity and reduce energy consumption. A model is presented based on transient coupled heat and mass transfer, to model, design and analyze the effects of geometrical characteristics of a honeycombed rotary desiccant wheel and its performance. Governing equations are solved numerically using finite volume method and the model is validate...
متن کامل