Refrigerant Migration Modeling During Shut-down And Start-up Cycling Transients
نویسندگان
چکیده
Refrigerant mass migration and redistribution have been regarded as factors influencing the performance of air conditioning and refrigeration systems. This paper presents a dynamic model of an R134a automotive A/C system that is able to capture the shut-down and start-up cycling dynamics including the refrigerant mass migration transients. Building upon recent work (Li and Alleyne, 2010), the heat exchangers are developed using a switched moving-boundary modeling framework, which maintains constant model structures but accommodates different model representations. Thermosys, a Matlab/Simulink toolbox, is introduced to simulate system transient behaviors. Model validations against experimental data show that the developed dynamic model can well predict the migration performance of the refrigerant mass across the components during shut-down transients, and the resulting refrigerant redistribution transients at start-up operations. The qualitative accuracy of the validation results demonstrates the potential of this dynamic modeling approach for control design and diagnosis in improving system start-up performance.
منابع مشابه
Refrigerant mass migration modeling and simulation for air conditioning systems
Refrigerant mass migration and redistribution are regarded as key factors affecting the cycling perfor mance of air conditioning and refrigeration systems. A dynamic model of an R134a automotive air conditioning system is presented as an example in this paper to capture the refrigerant migration during compressor shut-down and start-up operations. Model validation against experimental data dem...
متن کاملEvaluation of Transient Refrigerant Migration Modeling Approach on Automotive Air Conditioning Systems
Automotive air conditioning systems are subject to constantly changing operation conditions and steady state simulations are not sufficient to describe the actual performance. The refrigerant mass migration during transient events such as clutch-cycling or start-up bas a direct impact on the transient performance. It is therefore necessary to develop simulation tools which can accurately predic...
متن کاملTransient Refrigerant Migration and Oil Distribution of an R134a Automotive A/C System
Automotive fixed orifice tube (FOT) systems are especially prone to cycling losses due to their clutch cycling operation. Therefore, it is important to better understand the dynamics of the refrigerant and oil migration during transient events such as cycling and start-up . To measure the refrigerant mass and oil distribution of an automotive R134a FOT breadboard system, two ball valves around ...
متن کاملRefrigerant Mass and Oil Migration During Start-up Transient
A comparison of the start-up cooling capacities for an automotive R744 and an automotive R134a air conditioning system is presented. It is shown that development of the cooling capacities during start-up can be described with one correlation for both systems. The comparison of the cooling capacities and the redistribution of refrigerant mass during start-up suggest a strong relationship between...
متن کاملPCDD/F and other micropollutants in MSWI crude gas and ashes during plant start-up and shut-down processes.
Nonstationary combustion conditions at municipal solid waste incineration (MSWI) plants cause increased crude gas concentrations of polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF), and other products of incomplete combustion (PIC). Such transient conditions occur, e.g., during and after start-up processes in MSWI plants. The start-up and shut-down processes of a M...
متن کامل