Hadamard Slice Encoding for Reduced-FOV Single-Shot Diffusion-Weighted EPI

نویسندگان

  • E. U. Saritas
  • A. Shankaranarayanan
  • D. G. Nishimura
چکیده

Introduction: A reduced field-of-view (FOV) single-shot EPI (ss-EPI) method that uses a 2D echoplanar RF (2D-EPRF) excitation has recently been proposed for high-resolution DWI [1]. This method takes advantage of ss-EPI’s robustness against motion during diffusion encoding gradients. Furthermore, it allows for contiguous multi-slice imaging without the need for slice skip. However, there is a limit on the number of slices that can be imaged simultaneously, given by the number of slices that can fit between two adjacent sidelobes of the periodic 2D excitation profile (Fig. 1). In this work, we present two different Hadamard slice encoding schemes for the reduced-FOV method to double the number of slices without any SNR penalty. Methods: The excitation profile of the 2D-EPRF pulse, used in the aforementioned reduced-FOV method [1], is periodic in the slice-select (SS) direction as shown in Figure 1. A subsequent 180 RF pulse with crushers is designed to refocus only the main lobe of the excitation, suppressing the signal from the sidelobes and fat [1]. Because the adjacent slices are not excited, contiguous multi-slice imaging is compatible with this scheme. However, the periodicity of the excitation profile places a limit on the number of slices that can be imaged in a single TR. This limit is a function of the slice thickness (ΔdSS) and the distance between two adjacent sidelobes of the 2D excitation profile (Δdreplica): Nslices = Δdreplica / ΔdSS = Nblip / TBWSS. Here, Nblip is the number of blips in the 2D-EPRF pulse design [2], and TBWSS is the time-bandwidth product for the SS direction. Note that larger Nblip values (i.e., longer 2D-EPRF pulses) are needed to acquire more slices. For example, a 22 ms RF pulse is required for 6 slices for FOV of 3mm in PE direction. To achieve relatively short echo times (TE), we avoid using longer RF pulses. For certain applications such as the axial imaging of the spinal cord, it is desirable to acquire as many slices in a single TR as possible and avoid long scan times. In this work, we use Hadamard slice encoding (i.e., multiband excitation) to double the number of slices. This method encodes two slices to generate the following images: A=(Slice1+Slice2) and B=(Slice1-Slice2). In our case, this can be achieved in two different ways: 1) Main-lobe Hadamard encoding (Fig. 2.a): The slice thickness is doubled (i.e., ΔdSS*=2ΔdSS), which also doubles Δdreplica due to gradient scaling. Hadamard-encoding 180 o RF pulses are then applied to the main lobe to resolve two slices of thickness ΔdSS out of the thicker slice of 2ΔdSS. This scheme can resolve 2×Nslices slices. 2) Sidelobe Hadamard encoding (Fig. 3.a): Hadamardencoding 180 RF pulses are designed to select the two adjacent sidelobes of the 2D excitation profile. This way, the main lobe and one adjacent sidelobe can be resolved, again resulting in 2×Nslices slices. For both cases, Hadamard encoding was achieved using the method described in [2], which uses the Shinnar-Le Roux (SLR) RF pulse design algorithm [3]. The Hadamard modulation was applied to both the desired Bn(z) polynomial of the SLR transform and the corresponding RF pulses calculated by SLR transform. The β-value (defined in [3]) for both pulses were 0.4987, with TBW = 5. The main factor determining the pulse durations was the peak B1 value of 0.16 G. In vivo axial DWI images of the cervical spinal cord were acquired in healthy subjects on a 1.5T GE Excite scanner (40 mT/m gradients with 150 mT/m/ms slew rates) using an 8channel CTL coil. A 6-slice 2D-EPRF was used, which generated 12 slices with the Hadamard slice encoding 180 RF pulse in 2:52s scan time. 0.64x0.64 mm inplane resolution, 5 mm slice thickness, no slice spacing, 8x3 cm FOV, b = 500 s/mm, TE = 60ms. A partial k-space coverage of 62.5% was used for all scans, with TR = 3.6 s and ±62.5 kHz bandwidth. Refocusing reconstruction [4] was performed, with the central 12.5% of k-space treated as the “navigator” for each single-shot data, followed by a partial k-space homodyne reconstruction [5]. Results: Figures 2.b and 3.b show the results for the two proposed Hadamard slice encoding schemes. Note that there is residual crosstalk between Slice1 and Slice2 for the sidelobe Hadamard encoding scheme. The same may be true for the main lobe scheme, as well. However, since the slices are located right next to each other, any crosstalk will be less noticeable. Conclusion: It is shown that Hadamard slice encoding can be used to double the number of slices for the 2D-EPRF reduced-FOV method. Two unique ways of applying the Hadamard encoding are proposed. The “main lobe Hadamard encoding” has the advantage of localized crosstalk, i.e., crosstalk happens between neighboring slices, instead of a slice that is Nslicesx ΔdSS away. Also, the A=(Slice1+Slice2) case for this scheme produces a useful image with twice the slice thickness, whereas the image A in “sidelobe Hadamard encoding” is not useful on its own. An improved reconstruction is needed to minimize residual crosstalk.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DWI of the spinal cord with reduced FOV single-shot EPI.

Single-shot echo-planar imaging (ss-EPI) has not been used widely for diffusion-weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross-sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long re...

متن کامل

Multi-Slice Parallel Excitation Reduced FOV Imaging for Rodent EPI Applications

Introduction Echo-planar imaging (EPI) offers major advantages over conventional MR imaging, including reduced imaging time and the ability to image rapid physiologic processes [1]. However, signal decay and off-resonance effects limit the possible duration of the EPI echo train, requiring high resolution EPI to combine k-space signals from several sequential excitations. Multiple shot techniqu...

متن کامل

High-Resolution DWI outside the CNS using Reduced-FOV Single-Shot EPI

Introduction: Diffusion weighted imaging (DWI) has recently been recognized as a potential clinical tool for the diagnosis and treatment monitoring of cancer outside the central nervous system [1-3]. Even though single-shot EPI (ss-EPI) is the preferred method for these applications, its resolution is limited. Recently, a reduced field-of-view (FOV) method has been presented for high resolution...

متن کامل

Reduced FOV spinal muscle DWI with single-shot interleaved multi-slice inner volume stimulated echo DW-EPI

Introduction: Atrophy of spinal muscles is associated with degenerative disc disease, alignment disorders and eventually back pain. Diffusion-weighted (DW) MRI of skeletal muscle has been proposed as a sensitive marker of denervation-induced muscle atrophy [1]. However, DW-MRI of spinal muscles remains challenging due to the muscle short T2 and the sensitivity of single-shot EPI to off-resonanc...

متن کامل

Hadamard slice encoding for reduced-FOV diffusion-weighted imaging.

PURPOSE To improve the clinical utility of diffusion-weighted imaging (DWI) by extending the slice coverage of a high-resolution reduced field-of-view technique. THEORY Challenges in achieving high spatial resolution restrict the use of DWI in assessment of small structures such as the spinal cord. A reduced field-of-view method with 2D echo-planar radiofrequency (RF) excitation was recently ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008