Validation requirements for ambulatory blood pressure measuring systems.

نویسندگان

  • E O'Brien
  • F Mee
  • N Atkins
  • K O'Malley
چکیده

The increasing application of ambulatory blood pressure measurement in clinical practice has stimulated the manufacture of a large number of ambulatory systems which must be independently validated. The British Hypertension Society protocol for the evaluation of blood pressure measuring devices has now been used to evaluate eight ambulatory systems. Based on this experience recommendations are made for improving validation techniques for the evaluation of ambulatory devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The need for a standardized protocol for validating non-invasive ambulatory blood pressure measuring devices.

Increasing interest in ambulatory blood pressure measurement has resulted in the proliferation of non-invasive measurement systems. This paper discusses the problems associated with validation of these systems. There is an urgent requirement for a standardized protocol for validation of ambulatory systems which is practicable, universally applicable and which is acceptable to investigators, pub...

متن کامل

The British Hypertension kociety protocol for the evaluation of blood preskure measuring devices

Michael de Swiet*§, Paul L. ~adfie~dq, Douglas G. AltmanE, Martin Blandg, Andrew k oatss and Neil Atkins . Ba-und: With the increasing market~ng of automated and semi-automated devices for the measurement of blood pressuk, there is a need for potential pudhasen to be able to satisfy themselves that such dhices have been evaluated according to agreed criteria. To fulfil this need, the ~ritisk Hy...

متن کامل

Pulse wave velocity 24-hour monitoring with one-site measurements by oscillometry

This review describes issues for the estimation of pulse wave velocity (PWV) under ambulatory conditions using oscillometric systems. The difference between the principles of measuring the PWV by the standard method and by oscillometry is shown, and information on device validation studies is summarized. It was concluded that currently oscillometry is a method that is very convenient to use in ...

متن کامل

Evaluation of blood pressure measuring devices with special reference to ambulatory systems.

As ambulatory blood pressure measurement becomes more widely accepted in hypertension research and in the clinical management of high blood pressure, the number of devices available on the market has increased considerably, reflecting the clinical demand. These devices are expensive, both in terms of capital and running costs. As we rely increasingly on data produced by ambulatory systems, it b...

متن کامل

The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems.

With the increasing manufacture of expensive systems for the measurement of ambulatory blood pressure there is a need for potential purchasers to be able to satisfy themselves that the systems have been evaluated according to agreed criteria. The British Hypertension Society has, therefore, drawn up a protocol of requirements for the evaluation of these devices. This protocol incorporates many ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of hypertension. Supplement : official journal of the International Society of Hypertension

دوره 9 8  شماره 

صفحات  -

تاریخ انتشار 1991