Comparison of fifteen immunoassays for the measurement of serum MUC-1/CA 15-3 in breast cancer patients.

نویسندگان

  • Marie-France Pichon
  • Gaëlle Le Brun
  • Kamel Hacene
  • Jean-Pierre Basuyau
  • Jean-Marc Riedinger
  • Nicole Eche
  • Yvonne Fulla
  • Natacha Charlier-Bret
چکیده

BACKGROUND Quality control results for serum MUC-1/CA 15-3 assays have always shown large discrepancies. METHODS This multicentre study of 15 methods (labelled M1-M15) measured coded sera from 35 patients with breast cancer without recurrence (group 1), 46 patients at 1st metastasis (group 2), and 39 patients with advanced metastases (group 3). Results were compared using parametric statistics, ANOVA, principal component analysis, and receiver operating characteristic (ROC) curves. RESULTS Mean MUC-1/CA 15-3 concentrations varied widely (75.1-303.0 U/mL, 24.8%) among methods. The false positive (FP) rate for group 1 was 8/521 (1.5%); for group 2 and group 3 false negative (FN) results were 21/680 (3.1%) and 11/583 (1.9%), respectively. Using the ROC cut-offs, we found no FPs for group 1 and no FNs for group 3. However, group 2 showed 16 FNs. All p-values for Pearson's correlation were <0.0001 between methods, except for M11. When comparing methods using different antibodies, discordance rates reached a maximum of 15.2%. Principal component analysis revealed a grouping of methods using: CanAg monoclonal antibodies (mAbs) (M2, M7 and M12); Centocor/Fujirebio mAbs (M3-M6, M8-M10, M14-M15) and Biomira mAbs (M1 and M13); and Centocor/Fujirebio mAbs (M11). CONCLUSIONS Results were more consistent among methods using the same antibody type. Principal component analysis showed that antibody type was the strongest determinant of immunoassay results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Serum Level of Carcinoembryonic antigen, Prolactin, and Malondialdehyde in Patients Suffering from Breast Cancer and in Healthy individuals in Isfahan

 Background & Objective: One of the most prevalent types of cancer among women is breast cancer. The objective of this study is to compare the serum level of tumor marker of Carcinoembryonic Antigen (CEA), Prolactin, and oxidative marker Malondialdehyde (MDA) in patients with breast cancer and in control groups.  Materials & Methods: This case control study was carried out on the people wh...

متن کامل

Sensitivity and Specificity of CA 15-3 in Detection of Breast Cancer Recurrence

Background: The value of CA15-3(cancer antigen 15-3) marker in early detection of breast cancer recurrence has been studied in several prospective trials. But the results of these studies are different. This may be due to variable cutoff points used for analysis, different intervals between CA15-3 measurements and the differences between patients population. This study was done to examine the p...

متن کامل

Measurement of Serum Survivin to Discriminate Patients with Breast Cancer from Normal Subjects

Background and Aims: There is now an increasing body of evidence that survivin is a protein, expressed highly in breast cancer. The signaling interaction of protein survivin in breast cancer is still unclear, but physiological regulation of survivin seems to be linked to the breast cancer occurrence and severity of it. Materials and Methods: Serum samples were obtained from April 2015 to Novem...

متن کامل

Serum Level of HER-2 Extracellular Domain in Iranian Patients with Breast Cancer: A Follow-up Study

Background: A soluble form of HER-2/neu extracellular domain (sHER-2) is reported to be released in the sera of metastatic breast cancer patients. Objective: To measure the level of sHER-2 in sera of 115 breast cancer patients. Methods: Serial samples of 27 patients with metastasis, 18 non-metastatic patients, 15 patients in stage 0/I and 14 patients with accompanying benign breast disease were...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 47 8  شماره 

صفحات  -

تاریخ انتشار 2009