Investigating the use of a Gammatone filterbank for a cochlear implant coding strategy
نویسندگان
چکیده
BACKGROUND Contemporary speech processing strategies in cochlear implants (CIs) such as the Advanced Combination Encoder (ACE) use a standard Fast Fourier Transform (FFT) filterbank to extract envelopes. The assignment of the FFT bins to approximate the frequency resolution of the basilar membrane is only partly based on physiology, especially since the bins are distributed linearly below 1000Hz and logarithmically above 1000Hz. NEW METHOD A Gammatone filterbank which provides a closer approximation to the bandwidths of filters in the human auditory system could replace the standard FFT filterbank in the ACE strategy. An infinite impulse response (IIR) all-pole design of the Gammatone filterbank was compared to the FFT filterbank with 128, 256 and 512 points resolutions and the effect of the frequency boundaries of the filters was also investigated. RESULTS Melodic contour identification (MCI) and just noticeable difference (JND) experiments, both involving synthetic clarinet notes in octaves 3 and 4, were conducted with 6 normal hearing (NH) participants using noise vocoded stimuli; and 10 CI recipients just performed the MCI experiment. The MCI results for both NH and CI subjects, showed a significant effect of the filterbank on the percentage correct responses of the participants. COMPARISON WITH EXISTING METHODS The Gammatone filterbank can better resolve the harmonics of tested synthetic clarinet notes which led to better performances in the MCI experiment. CONCLUSIONS The total delay of the Gammatone filterbank can be made smaller than the delay of the FFT filterbank with the same frequency resolution at low frequencies.
منابع مشابه
Analyzing Auditory Representations for Sound Classification with Self-organizing Neural Networks
Three different auditory representations—Lyon’s cochlear model, Patterson’s gammatone filterbank combined with Meddis’ inner hair cell model, and mel-frequency cepstral coefficients—are analyzed in connection with self-organizing maps to evaluate their suitability for a perceptually justified classification of sounds. The self-organizing maps are trained with a uniform set of test sounds prepro...
متن کاملComparison of IIR Filterbanks and FFT Filterbanks in Cochlear Implant Speech Processing Strategies
The first stage of all cochlear implant speech processing strategies is a filterbank which decomposes the speech signal into several frequency bands. Two types of filterbanks can be used to achieve this goal and mimic the spectral analysis performed within the cochlea. The first is based on the Fast Fourier Transform (FFT). The second type of filterbank is composed of Infinite Impulse Response ...
متن کاملEvaluation of a new spectral peak coding strategy for the Nucleus 22 Channel Cochlear Implant System.
Sixty-three postlinguistically deaf adults from four English-speaking countries participated in a 17-week field study of performance with a new speech coding strategy, Spectral Peak (SPEAK), and the most widely used strategy, Multipeak (MPEAK), both of which are implemented on wearable speech processors of the Nucleus 22 Channel Cochlear Implant System; MPEAK is a feature-extraction strategy, w...
متن کاملAn investigation of non-uniform bandwidths auditory filterbank in audio coding
This paper presents an investigation on the use of non-linear auditory filterbank in wideband audio coding. The perceptually based parameterization of the audio signal using gammatone filterbank is examined and discussed. Conventional gammatone filters requires high order FIR filters in the synthesis stage which introduces long delay and large computation cost. Here, a simple and efficient synt...
متن کاملInvestigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کامل