Validation of noninvasive measurements of cardiac output in mice using echocardiography.

نویسندگان

  • François Tournoux
  • Bodil Petersen
  • Hélène Thibault
  • Lin Zou
  • Michael J Raher
  • Baptiste Kurtz
  • Elkan F Halpern
  • Miguel Chaput
  • Wei Chao
  • Michael H Picard
  • Marielle Scherrer-Crosbie
چکیده

BACKGROUND Although multiple echocardiographic methods exist to calculate cardiac output (CO), they have not been validated in mice using a reference method. METHODS Echocardiographic and flow probe measurements of CO were obtained in mice before and after albumin infusion and inferior vena cava occlusions. Echocardiography was also performed before and after endotoxin injection. Cardiac output was calculated using left ventricular volumes obtained from an M-mode or a two-dimensional view, left ventricular stroke volume calculated using the pulmonary flow, or estimated by the measurement of pulmonary velocity time integral (VTI). RESULTS Close correlations were demonstrated between flow probe-measured CO and all echocardiographic measurements of CO. All echocardiographic-derived CO overestimated the flow probe-measured CO. Two-dimensional image-derived CO was associated with the smallest overestimation of CO. Interobserver variability was lowest for pulmonary VTI-derived CO. CONCLUSION In mice, CO calculated from two-dimensional parasternal long-axis images is most accurate when compared with flow probe measurements; however, pulmonary VTI-derived CO is subject to less variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

Validation of high-resolution echocardiography and magnetic resonance imaging vs. high-fidelity catheterization in experimental pulmonary hypertension.

High-frequency echocardiography and high-field-strength magnetic resonance imaging (MRI) are new noninvasive methods for quantifying pulmonary arterial hypertension (PAH) and right ventricular (RV) hypertrophy (RVH). We compared these noninvasive methods of assessing the pulmonary circulation to the gold standard, cardiac catheterization (micromanometer-tipped catheters), in rats with monocrota...

متن کامل

Doppler echocardiographic measurement of aortic valve area in aortic stenosis: a noninvasive application of the Gorlin formula.

Thirty adult patients with aortic stenosis had Doppler echocardiography within 1 day of cardiac catheterization. Noninvasive measurement of the mean transaortic pressure gradient was calculated by applying the simplified Bernoulli equation to the continuous wave Doppler transaortic velocity recording. Stroke volume was measured noninvasively by multiplying the systolic velocity integral of flow...

متن کامل

Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine.

The determination of blood flow, i.e. cardiac output, is an integral part of haemodynamic monitoring. This is a review on noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. We present the underlying principles and validation data of the following technologies: thoracic electrical bioimpedance, thoracic bioreactance, vascular unloading technique, pulse...

متن کامل

Declaration of Interest Declaration of Interest Challenges with Improving Outcomes after Emergency Surgery

1 Bataille B, Bertuit M, Mora M, et al. Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care. Br J Anaesth 2012; 109: 879–86 2 Ishihara H, Okawa H, Tanabe K, et al. A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors. J Clin Monit Comput 2004; 18: 313–20 3 Yamada T, Tsutsui M, Sugo Y,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2011