Full-capillary sample stacking/sweeping-MEKC for the separation of naphthalene-2,3-dicarboxaldehyde-derivatized tryptophan and isoleucine.

نویسندگان

  • Chun-Min Shih
  • Cheng-Huang Lin
چکیده

In an attempt to improve the sensitivity of detection in capillary electrophoresis (CE), a novel online sample-concentration method, full-capillary sample stacking (FCSS)/sweeping-micellar electrokinetic chromatography (sweeping-MEKC) mode, is proposed. Naphthalene-2,3-dicarboxaldehyde (NDA)-derivatized tryptophan and isoleucine were selected as model compounds. In the initial step, the weakly acidic compounds, dissolved in a low-conductivity buffer (35.1 microS/cm; apparent ph (pH*) in a mixed solution of acetonitrile/methanol/water, 4.6), fill the entire capillary, two vials of a high-conductivity buffer (2.06 mS/cm; pH* 2.0) are placed on each end, and a negative polarity is then applied. Under these conditions, the direction of the electroosmotic flow (EOF) is toward the inlet. Meanwhile, the anionic analytes move in the reverse direction and are neutralized and stacked at the boundary of a dynamic pH-junction (between the sample matrix and the nonmicellar background solution (BGS)). When the sample concentration is completed, the BGS is quickly changed to solutions containing SDS-BGS for the subsequent separation. Since the mobility of SDS-analytes is then greater than the EOF, the following steps occur by the sweeping (for focusing) and MEKC (for separation) mode. Using these steps, a full-capillary sample injection/separation can be achieved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the use of single capillaries and coupled capillaries based on micellar electrokinetic chromatography (MEKC) and sweeping-MEKC modes.

The use of single capillaries (25 and 50 microm inner diameter (ID)) and coupled capillaries of different diameters (100-50 and 75-25 microm ID) based on micellar electrokinetic chromatography (MEKC) and sweeping-MEKC modes is compared and reported. Naphthalene-2,3-dicarboxaldehyde (NDA)-derivatized dopamine was selected as the model compound by examining the fluorescence intensity when a viole...

متن کامل

Large-volume sample sweeping with a high theoretical plate number using a coupled-capillary in capillary electrophoresis.

A large-volume sample injection (> 5 microL) with an extremely high theoretical plate number (N > 10(7)) was achieved when the sweeping-MEKC mode and a coupled-capillary (100 - 50 microm i.d.) were simultaneously used in a capillary electrophoresis (CE) separation. A low-cost and compact violet-LED ( approximately 2 mW) was used as the fluorescence excitation source. As a result, the theoretica...

متن کامل

Violet light emitting diode-induced fluorescence detection combined with on-line sample concentration techniques for use in capillary electrophoresis.

The first application of a violet light-emitting diode (LED) for fluorescence detection in capillary electrophoresis (CE) is described. The utility of violet LED (peak emission wavelength at 410 nm, approximately 2 mW) for fluorescence detection is demonstrated by examining reserpine and dopamine-labeled NDA (naphthalene-2,3-dicarboxaldehyde), respectively. The detection limit for reserpine was...

متن کامل

Methanol plug assisted sweeping-micellar electrokinetic chromatography for the determination of dopamine in urine by violet light emitting diode-induced fluorescence detection.

The use and limitations of a methanol plug assisted sweeping-micellar electrokinetic chromatography (sweeping-MEKC) method is described. Using naphthalene-2,3-dicarboxaldehyde (NDA)-labeled dopamine as a model compound, this new method was also used in the determination of dopamine in actual urine samples. An inexpensive violet light emitting diode (LED) was used for the light source, because t...

متن کامل

Processes involved in sweeping as sample enrichment method in cyclodextrin-modified micellar electrokinetic chromatography of hydrophobic basic analytes.

Sweeping is an enrichment method in MEKC, which includes following steps: stacking/destacking of the micelles, sweeping of analyte by the stacked/destacked micelles, destacking/stacking of the swept analyte zone and additional focusing/defocusing due to the retention factor gradient effect (RFGE). In this study, we investigate additional processes, regarding online focusing in cyclodextrin-modi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Electrophoresis

دوره 26 18  شماره 

صفحات  -

تاریخ انتشار 2005