Diagnostic value of 123I-ioflupane and 123I-iodobenzamide SPECT scans in 248 patients with parkinsonian syndromes.
نویسندگان
چکیده
BACKGROUND SPECT is one of the most employed techniques in the diagnostic workup of idiopathic Parkinson's disease (IPD). Despite its widespread use, the exact diagnostic accuracy of this technique in parkinsonian syndromes remains controversial. METHODS In this study, we investigated the diagnostic accuracy of an initial (123)I-ioflupane (FP-CIT) and/or (123)I-iodobenzamide (IBZM) SPECT to differentiate between IPD and other parkinsonian disorders. 248 patients underwent a SPECT scan because of an as yet unclassified parkinsonian syndrome in our clinic between 2001 and 2006. Gold standard was the clinical diagnosis derived from the latest available clinical record, or, when this was not possible, a new complete physical and neurological examination by a blinded movement disorder specialist neurologist. Mean follow-up between SPECT and the latest clinical information was 18 months (range 3 months to 5 years). RESULTS 223 of the 248 patients were clinically definitely diagnosed after follow-up: IPD 127, atypical parkinsonian syndromes (APS) 27, essential tremor (ET) 22, vascular parkinsonism (VP) 16, drug-induced parkinsonism (DIP) 5, doubt between PD and APS 2, other diseases without dopaminergic involvement 24. The mean odds ratio (95% CI) for FP-CIT SPECT's ability to distinguish between IPD and ET was 82 (11-674); between IPD and VP 61 (8-490); between IPD and DIP 36 (2-697) and between IPD and APS was 1 (0-4). The odds ratio for the IBZM SPECT tracer to differentiate between IPD and APS was 7 (2-17). CONCLUSIONS FP-CIT SPECT is accurate to differentiate patients with IPD from those with ET, and IPD from VP and DIP. The accuracy of both FP-CIT and IBZM SPECT scans to differentiate between IPD and APS is low.
منابع مشابه
Clinical utility of dopamine transporter single photon emission CT (DaT-SPECT) with (123I) ioflupane in diagnosis of parkinsonian syndromes
The diagnosis of movement disorders including Parkinson's disease (PD) and essential tremor is determined through clinical assessment. The difficulty with diagnosis of early PD has been highlighted in several recent clinical trials. Studies have suggested relatively high clinical diagnostic error rates for PD and essential tremor. This review was undertaken to clarify the utility of DaT-SPECT i...
متن کاملImprovement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...
متن کاملUtility of 123I-MIBG Standardized Uptake Value in Patients with Refractory Pheochromocytoma and Paraganglioma
Objective(s): Single-photon emission computed tomography (SPECT) using metaiodobenzylguanidine (MIBG) is an important diagnostic tool for the treatment of refractory pheochromocytoma and paraganglioma (PPGL). Owing to the difficulty of SPECT quantification, the tumour-to-background ratio (TBR) is used to assess disease activity. However, the utility of TBR is limited o...
متن کاملAccumulation of 123I-Ioflupane Is a Useful Marker of the Efficacy of Selegiline Monotherapy in Drug-Naïve Parkinson’s Disease
Background: Selegiline enhances the patient's endogenous dopamine by inhibiting dopamine metabolism. The efficacy of selegiline monotherapy for drug-naïve Parkinson's disease (PD) patients may depend on the degree of dopaminergic neuronal degeneration. 123I-Ioflupane single photon emission computed tomography (SPECT) and 123I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy are diagnosti...
متن کاملDevelopment of an 123I-metaiodobenzylguanidine Myocardial Three-Dimensional Quantification Method for the Diagnosis of Lewy Body Disease
Objective(s): We recently developed a new uptake index method for 123I-metaiodobenzylguanidine (123I-MIBG) heart uptake measurements by using planar images (radioisotope angiography and planar image) for the diagnosis of Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies(DLB). However, the diagnostic accuracy of the uptake index was approximately equal to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European neurology
دوره 59 5 شماره
صفحات -
تاریخ انتشار 2008