Sensitivity of the IL 282 Co-oximeter to low hemoglobin concentration and high proportions of methemoglobin.

نویسندگان

  • H L Sehgal
  • L R Sehgal
  • A L Rosen
  • R DeWoskin
  • S Gould
  • G S Moss
چکیده

dard to those of the chromatographic standard (25 mg of HPPH and 50 mg of hexobarbital, dissolved in 1 L of methanol). Free HPPH was also measured by comparison to the chromatographic standard after serum protein precipitation with acetonitrile containing the internal standard (1). Table 2 presents these results. We believe that these concentrations are sufficient to increase the EMIT phenytomn values. We conclude that phenytoin values obtained by EMIT assay for patients with impaired renal function should be cautiously interpreted. We thank the technologists of the Special Chemistry Section for their assistance in performing the assays, and Dr. Andrew Wilson of Presbyterian Hospital for his clinical investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining methemoglobin in blood by zero-crossing-point first-derivative spectrophotometry.

We determined methemoglobin in blood by zero-crossing-point first-derivative spectrophotometry. After lysis of erythrocytes, hemoglobin was converted into oxyhemoglobin and the first derivative spectrum was recorded between 405 and 425 nm. At the exact point where the first-derivative spectrum of oxyhemoglobin was zero ("zero-crossing point"), the first-derivative value of oxyhemoglobin and met...

متن کامل

The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration.

Intraoperative early detection of anemia, identifying toxic levels of carboxyhemoglobin after carbon monoxide exposure and titrating drug dosage to prevent toxic levels of methemoglobin are important goals. The pulse oximeter works by illuminating light into the tissue and sensing the amount of light absorbed. The same methodology is used by laboratory hemoglobinometers to measure hemoglobin co...

متن کامل

Measurement of carboxyhemoglobin and total hemoglobin by five specialized spectrophotometers (CO-oximeters) in comparison with reference methods.

We measured total hemoglobin (CtHb) and carboxyhemoglobin (COHb) in 100 patients' blood samples by using five specialized spectrophotometers (CO-oximeters)--IL 482 CO-Oximeter, Corning 2500 CO-oximeter, Radiometer OSM 3 Hemoximeter, Corning 270 CO-oximeter, and the AVL 912 CO-Oxylite--and compared the results with those obtained with the manual cyanmethemoglobin method and a gas-chromatographic...

متن کامل

Novel Perioperative Utilities of the Newer Co-Oximetery Parameters: A Practical Review

The radical-7 signal extraction technology (SET) Masimo pulse co-oximeter has raised the technology bar with non invasive and continuous measurement of haemoglobin, carboxy haemoglobin and methemoglobin and newer parameters like perfusion index, pleth variability index and acoustic respiratory index. These can be measured intraoperatively and in the critical care setup. We reviewed the current ...

متن کامل

Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.

BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 50...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 1980