We have developed an instrument for monitoring real-time PCR using fluorescence anisotropy, enabling an assay chemistry in which the fluorescence from a labeled primer elucidates amplification. The instrument holds the sample temperature constant to within +/-0.03 degrees C during measurement in the extension phase of each PCR cycle and achieves 0.116 mP FA resolution. Primer conjugation with Alexa-Fluor 488, when compared with other fluorophores, is shown to provide the greatest FA range between primer and product. Comparable reproducibility and linearity of the crossing point for a range of target copy numbers is observed between the FA-based assay run in our instrument and the SYBR green assay run in commercial instrumentation. Reproducibility is also consistent with Poisson-distributed experimental error in aliquoting starting copies, a theoretical limit to instrument/assay performance.
منابع مشابه
Rapid Detection of COVID-19 by RT-LAMP PCR Technique and its Comparison with Real-Time RT-PCR Method
Rapid antigen and antibody, serological tests, and RT ‑ PCR-based molecular methods are widely used for the detection of microorganisms worldwide. Objectives: This study aimed by Isothermal nucleic acid amplification techniques to detect the covid-19. Methods: In this study, 200 samples of nasopharynx and oropharynx were collected from Jamaran Heart Hospital in Tehran. Covid -19 was exami...
متن کاملFrequency of Human Herpesvirus 6 (HHV-6) in Pterygium Using Real-Time PCR Based on SYBR-Green I Fluorescence
ABSTRACT Background and objectives: Pterygium is a non-cancerous growth of conjunctival tissue that can extend onto the corneal surface. The presence of some oncogenic viruses in pterygium and the neoplastic nature of these lesions led us to the postulated involvement of the viruses in the etiology of pterygium. Given the association of human herpesvirus 6 (HHV-6) with ocular disea...
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کاملOptimization of Real Time PCR for Precise Measurement of HER2 Overexpression in Breast Cancer Specimens
Background: Breast cancer is one of the most prevalent malignancies among women in various countries. HER2 overexpression, which is due to different reasons, occurs in 20-30% of breast cancers. HER2 gene encodes an 185kDa transmembrane glycoprotein with 1255 amino acids. This active product triggers downstream intracellular signaling pathways inducing cell proliferation and cell survival. These...
متن کاملAbsolute quantification of murine interleukine-4, interleukine- 10 and interferon-γ gene transcripts using Real Time PCR
The study of cytokines gene expression is quite important in various conditions of health and disease for the evaluation of clinical responses to new vaccination approaches. An absolute quantification is based on a calibration curve and production of standard controls to achieve more reliable results than in relative system. In this study we attempted to construct standard controls to evaluate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 77 16 شماره
صفحات -
تاریخ انتشار 2005