Dynamic two-dimensional fluorescence correlation spectroscopy. Generalized correlation and experimental factors.
نویسندگان
چکیده
Dynamic two-dimensional fluorescence correlation spectroscopy (2D FCS) is presented in the general form. Dynamic 2D FCS evaluates the time correlation function between two wavelength axes when an external perturbation is applied to the sample. It displays the vibronic features with similar time response functions in the synchronous correlation spectrum and the features with different time responses in the asynchronous correlation spectrum. The correlation analysis allows detailed assignments of the vibronic spectra of multicomponent samples. The emission-emission 2D FCS has proven to be able to resolve spectra with substantial overlaps, of species in equilibrium with each other, and of reacting species whose kinetic constants are linked and multiexponential. Similarly, the correlation analysis between excitation wavelengths allows the assignment of the excitation bands to fluorescent components. When a sinusoidal light source is used to excite the sample, the excitation-emission correlation requires the collection of only four spectra, two in-phase and two quadrature. The two-dimensional excitation-emission correlation analysis uncovers the association between the excitation and the emission vibronic features, enabling the complete assignment of the component spectra. The band associations and spectral assignments are facilitated by the two-dimensional phase map that is constructed from the synchronous and asynchronous correlation spectra. Spectral resolution can be optimized by varying the frequency of excitation and is not influenced by the detector phase angle used to collect the spectra. The resolution power of the 2D FCS is demonstrated with the retrieval of the anthracene emission spectrum from a pyrene-anthracene mixture when it contributes only 4% to the total fluorescence intensity.
منابع مشابه
Fast two-dimensional fluorescence correlation spectroscopy technique for tea quality detection.
A fast two-dimensional fluorescence correlation spectroscopy technique based on light emitting diodes is developed, which uses light intensity and excitation wavelength as quickly changeable and easily controllable external perturbations. A compact and automatic system is set up to detect tea quality. A partial least square regression method is used to create predictive models for tea grades. C...
متن کاملDetection and Characterization of Human Teeth Caries Using 2D Correlation Raman Spectroscopy
Background: Carious lesions are formed by a complex process of chemical interaction between dental enamel and its environment. They can cause cavities and pain, and are expensive to fix. It is hard to characterize in vivo as a result of environment factors and remineralization by ions in the oral cavity. Objectives: The development of a technique that gives early diagnosis which is non-invasi...
متن کاملTheory of fluorescence correlation spectroscopy at variable observation area for two-dimensional diffusion on a meshgrid
It has recently been proposed, with the help of numerical investigations, that fluorescence correlation spectroscopy at variable observation area can reveal the existence of a meshgrid of semipermeable barriers hindering the two-dimensional diffusion of tagged particles, such as plasmic membrane constituents. We present a complete theory confirming and accounting for these findings. It enables ...
متن کاملMeasuring and imaging diffusion with multiple scan speed image correlation spectroscopy.
The intracellular mobility of biomolecules is determined by transport and diffusion as well as molecular interactions and is crucial for many processes in living cells. Methods of fluorescence microscopy like confocal laser scanning microscopy (CLSM) can be used to characterize the intracellular distribution of fluorescently labeled biomolecules. Fluorescence correlation spectroscopy (FCS) is u...
متن کاملComparison of different fluorescence fluctuation methods for their use in FRET assays: monitoring a protease reaction.
We compare the accuracy of a variety of Fluorescence Fluctuation Spectroscopy (FFS) methods for the study of Förster Resonance Energy Transfer (FRET) assays. As an example, the cleavage of a doubly labeled, FRET-active peptide substrate by the protease Trypsin is monitored and analyzed using methods based on fluorescence intensity, Fluorescence Correlation Spectroscopy (FCS) and Fluorescence In...