Performance of the Roche Total Mycophenolic Acid® assay on the Cobas Integra 400®, Cobas 6000® and comparison to LC-MS/MS in liver transplant patients.

نویسندگان

  • An-Sofie C Decavele
  • Niels Favoreel
  • Fien Vander Heyden
  • Alain G Verstraete
چکیده

BACKGROUND Mycophenolic acid (MPA) is an immunosuppressant for which therapeutic drug monitoring (TDM) is performed for optimal prophylaxis and avoidance of toxicity in transplant patients. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for TDM of MPA. There have been several method comparisons of the Roche Total MPA assay, but none have been performed with respect to liver transplant patients. METHODS We validated the Roche Total MPA assay on the Cobas Integra 400 and Cobas 6000 and compared it to a validated LC-MS/MS (API 2000™) method. Fifty-five EDTA plasma samples from liver transplant patients were measured with the Roche assay on these platforms and compared to the LC-MS/MS results. RESULTS Validation of the LC-MS/MS, Cobas Integra 400 and 6000 was performed with good results. The LC-MS/MS/Integra 400/Cobas 6000 were linear up to 30, 15 and 17 mg/L, respectively. Imprecision was <10% for LC-MS/MS and <7% for the Roche assay on both platforms. The samples showed good agreement with LC-MS/MS. Passing-Bablok regression analysis showed Cobas Integra (mg/L)=1.02 × LC-MS/MS (mg/L)-0.50 and Cobas 6000 (mg/L)=0.98 × LC-MS/MS-0.47. CONCLUSIONS The Roche Total Mycophenolic Acid-assay is suitable for measuring total MPA in plasma from liver transplant patients and is a good alternative for LC-MS/MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of the My5-FU™ immunoassay and LC-MS/MS in monitoring the 5-fluorouracil plasma levels in cancer patients.

BACKGROUND Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring...

متن کامل

A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry

INTRODUCTION Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS). MATERIALS AND METHODS One hundred venous blood samples were randomly selected ...

متن کامل

The Roche Total Mycophenolic Acid® assay: An application protocol for the ABX Pentra 400 analyzer and comparison with LC–MS in children with idiopathic nephrotic syndrome

BACKGROUND For TDM of mycophenolate acid (MPA), the Roche Total Mycophenolic Acid® assay based on the inhibition of recombinant inosine monophosphate dehydrogenase (IMPDH) has been shown to be a simple and reliable alternative to chromatographic methods. We have adapted this assay on the ABX Pentra 400 analyzer (HORIBA). OBJECTIVE To investigate the analytical performances of the Roche Total ...

متن کامل

Performance evaluation of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, version 2.0, for detection and quantification of hepatitis C virus RNA.

To evaluate the analytical performance and explore the clinical applicability of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, v2.0 (CAP/CTM v2.0), a platform comparison was performed on panels and diagnostic samples with the Roche cobas AmpliPrep/cobas TaqMan HCV test (CAP/CTM v1.0), the Siemens Versant HCV RNA 3.0 branched DNA (bDNA) test, the Abbott m2000 RealTime HCV assay (Realtime ...

متن کامل

Comparison of Efficacy and Safety of Two Different Enoxaparin Products in Prevention of Venous Thromboembolism Following Major Obstetric-gynecological Surgeries: An Open-label Randomized Clinical Trial

Venous thromboembolism (VTE) occurs in about 5 percent of patients undergoing major abdominal surgeries. Prophylaxis of VTE is recommended using unfractionated heparin (UF) or low molecular weight heparin (LMWH) in high-risk patients. In spite of advantages and confirmed cost-effectiveness of LMWH, high costs of enoxaparin branded preparations limit its use. We aimed to compare the efficacy and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 49 7  شماره 

صفحات  -

تاریخ انتشار 2011