Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial.
نویسندگان
چکیده
In a prospective trial, biodegradable polyglycolic acid rods were compared with Kirschner wires for fixation of wrist fractures (Frykman types I, II, V and VI). Fifteen patients were randomly assigned to each treatment group. There was no significant difference between the groups with regard to age, sex ratio and fracture type. Kapandji's pinning technique was used in all cases. There were no significant differences in the results obtained in both groups at final follow-up. At three months and six months the functional results of the Kirschner-wire group were, however, significantly better (p < 0.05), due to numerous transient complications from foreign-body reactions to the polyglycolic acid rods. The use of polyglycolic acid rods is therefore not recommended for the fixation of distal radial fractures.
منابع مشابه
Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial
OBJECTIVES To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. DESIGN A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. SETTING 18 trauma centres in the United Kingdom. PARTICIPANTS 461 adults with a dorsally displaced ...
متن کاملBridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial.
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-loc...
متن کاملUK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius
BACKGROUND In high-income countries, 6% of all women will have sustained a fracture of the wrist (distal radius) by the age of 80 years and 9% by the age of 90 years. Advances in orthopaedic surgery have improved the outcome for patients: many such fractures can be treated in a plaster cast alone, but others require surgical fixation to hold the bone in place while they heal. The existing evide...
متن کاملOpen intramedullary Kirschner wire versus screw and plate fixation for unstable forearm fractures in children.
PURPOSE To compare the outcomes of intramedullary Kirschner wire versus screw and plate fixation for unstable forearm fractures in children aged older than 10 years. METHODS Records of 32 children aged 10 to 15 (mean, 12) years with displaced fractures of the radius and ulna were retrospectively reviewed. 17 boys and 4 girls underwent intramedullary Kirschner wiring, whereas 10 boys and one g...
متن کاملPercutaneous Kirschner-wire fixation for displaced distal forearm fractures in children.
A prospective study was conducted to evaluate the efficacy of percutaneous Kirschner-wire fixation for the management of high-risk distal forearm fractures in children. Thirty two children (22 boys & 10 girls) with displaced fractures of the distal third of the radius with or without ulnar fractures were managed by closed reduction and percutaneous Kirschner-wire fixation. Their average age was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 74 6 شماره
صفحات -
تاریخ انتشار 1992