A screen test for rubella haemagglutination inhibition antibodies.
نویسندگان
چکیده
The findings agree closely with those of Hobbs and Aw (1968). The isoamylase patterns of normal plasma and urine are similar, though the activity in urine is greater. Three bands are usually found in normal urine, the slower, and usually more distinct, band being the pancreatic component, and the faster those derived from salivary gland. The activities of these isoenzymes in plasma appear to be equal. In cases of pancreatitis, the slower band becomes much more distinct, and often further activity can be detected between this and the salivary bands. This is a similar pattern to that found in pancreatic extract. Saliva shows three bands, all faster than those of pancreatic origin, and a similar pattern is seen in the plasma in parotitis, with an increase in the fastest band. These appearances can all be clearly seen in the
منابع مشابه
Comparison of passive haemagglutination and haemagglutination-inhibition techniques for detection of antibodies to rubella virus.
Because of the technical problems and length of time involved in the satisfactory performance of the haemagglutination-inhibition test for detection of rubella-specific antibodies, a commercially available passive haemagglutination (PHA) kit utilising rubella antigen-sensitised human erythrocytes was tested for its suitability for use in diagnostic laboratories. The immune response to acute rub...
متن کاملSimplified method for the rubella haemagglutination inhibition screening test.
A modification of the rubella haemagglutination inhibition (HAI) test in which both pretreatment and serum titration are carried out in wells of the same microtitre plate saves time, labour, and materials and gives results comparable to a conventional HAI procedure.
متن کاملComparison of radial haemolysis with haemagglutination inhibition in estimating rubella antibody.
Radial haemolysis (RH) for assaying rubella antibody was studied in parallel tests with haemagglutination-inhibition (HAI) on 1102 sera from adult women. Simple to perform and economical in reagents, the RH test is as sensitive as the HAI test and is a useful method of screening antenatal and other sera for rubella immunity. It detects IgG but not IgM antibody.
متن کاملCongenital rubella affecting an infant whose mother had rubella antibodies before conception.
A woman who had had high titres of rubella antibodies some months before she became pregnant gave birth to an infant in whom congenital rubella was confirmed at 4 months. Rubella haemagglutination inhibition tests, complement fixation tests, and immunofluorescence tests with anti-human IgG were carried out on sera from the mother. Rubella antibody titres in sera obtained in March 1971, seven an...
متن کاملStudy of discrepancies in rubella haemagglutinin titrations and a reappraisal of diluents used in the rubella haemagglutination inhibition technique.
To elucidate inconsistencies in rubella haemagglutinin assays the components of the assay technique were examined. The results of carefully controlled assays of rubella haemagglutinin antigens from different sources in various plates and diluents with four species of indicator cells are reported. The quality and quantity of gelatin in the dextrose-gelatin-veronal buffered diluent commonly used ...
متن کاملA modified rubella HI test using prestandardized reagents.
A modified haemagglutination inhibition test for rubella antibodies using prestandardized freeze-dried reagents was compared to a "standard" method. Tests of 707 serum samples showed that the modified test was sensitive and reliable by both macrotitration and microtitration techniques. The minor disadvantages of some reduction in antibody level when rubella sera were tested within one week of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 25 3 شماره
صفحات -
تاریخ انتشار 1972