Analysis of heterogeneous uptake by nanoparticles via differential mobility analysis-drift tube ion mobility spectrometry.
نویسندگان
چکیده
Improved methods are needed to study sorption of vapor molecules by particles in the gas phase (heterogeneous uptake), which is an important process in both natural and engineered environments. Here, a new measurement system, composed of a differential mobility analyzer (DMA) and drift tube ion mobility spectrometer (DTIMS) in series, is used to examine the heterogeneous uptake of water vapor by 2.85-7.6 nm particles composed of lithium and sodium iodide. The extent of heterogeneous uptake is determined by controlling the relative humidity of the drift region in the DTIMS in the 0-30% range (in air at atmospheric pressure and room temperature), and is quantified via the dimensionless growth factor (GF), i.e. the ratio of the mobility diameter of particles at a prescribed relative humidity relative to their mobility diameter under dry conditions. The precision in GF estimation of the DMA-DTIMS system is shown to be below 0.2%. An analytical equation to calculate the growth factor, based upon predictions of the equilibrium constants for the successive uptake of vapor molecules by particles, is also presented. While the equation is sufficiently general to enable comparison between measured GFs and predictions from any theoretical expression for equilibrium constants, we specifically compare measurements to GF predictions based on the classical Kelvin-Thomson-Raoult (KTR) model for the vapor pressure of a small particle, with consideration of the influence of the ion-dipole potential on water vapor-nanoparticle collisions. It is shown that KTR calculations drastically underpredict the extent of heterogeneous uptake for the examined nanoparticles.
منابع مشابه
Application of Ion Mobility Spectrometry for Determination of Morphine in Human Urine
In this study, a rapid, simple and sensitive ion mobility spectrometry (IMS) method with corona discharge as ionization source was described for the morphine determination in human urine. Morphine was extracted and purified from urine samples using solid phase extraction procedure with C18 column. It can offer the clean extracts which no extra peaks were observed in IMS. Under operating experim...
متن کاملDETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کاملCollision cross section calibrants for negative ion mode traveling wave ion mobility-mass spectrometry.
Unlike traditional drift-tube ion mobility-mass spectrometry, traveling-wave ion mobility-mass spectrometry typically requires calibration in order to generate collision cross section (CCS) values. Although this has received a significant amount of attention for positive-ion mode analysis, little attention has been paid for CCS calibration in negative ion mode. Here, we provide drift-tube CCS v...
متن کاملIon Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
■ CONTENTS Basic Ion Mobility Concepts 1423 Electrostatic and Electrodynamic Fields 1423 Resolving Power 1423 Ion Mobility Techniques 1424 Temporally-Dispersive Ion Mobility 1424 Drift Tube Ion Mobility Spectrometry (DTIMS) 1425 Traveling Wave Ion Mobility Spectrometry (TWIMS) 1426 Overtone Mobility Spectrometry (OMS) 1427 Confinement and Mobility-Selective Release 1428 Trapped Ion Mobility Spe...
متن کاملEvaluation of micro-electrospray ionization with ion mobility spectrometry/mass spectrometry
In recent years, the resolving power of ion mobility instruments has been increased significantly, enabling ion mobility spectrometry (IMS) to be utilized as an analytical separation technique for complex mixtures. In theory, decreasing the drift tube temperature results in increased resolution due to decreased ion diffusion. However, the heat requirements for complete ion desolvation with elec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical chemistry chemical physics : PCCP
دوره 16 15 شماره
صفحات -
تاریخ انتشار 2014