Metrology Institute Comparison of Guarded - Hot - Plate Apparatus

نویسنده

  • Robert R. Zarr
چکیده

Two national metrology institutes have conducted an international interlaboratory comparison on thermal conductivity for two thermal insulation reference materials. The Laboratoire national de métrologie et d’essais (LNE), France, and the National Institute of Standards and Technology (NIST), United States, present measurements obtained by the guarded-hot-plate method. The study involved two materials: expanded polystyrene board (EPS) and fibrous glass board (FGB). The EPS was provided by the LNE and is issued as a transfer specimen; the FGB provided by NIST was issued as Standard Reference Material (SRM) 1450c. For each reference material, the study was based on four independent measurements at a mean temperature of 24°C and two additional mean temperatures of 10°C and 35°C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Uncertainties for the NIST 1016 mm Guarded-Hot-Plate Apparatus: Extended Analysis for Low-Density Fibrous-Glass Thermal Insulation

An assessment of uncertainties for the National Institute of Standards and Technology (NIST) 1016 mm Guarded-Hot-Plate apparatus is presented. The uncertainties are reported in a format consistent with current NIST policy on the expression of measurement uncertainty. The report describes a procedure for determination of component uncertainties for thermal conductivity and thermal resistance for...

متن کامل

Thermal Conductivity of Magnesium Oxide From Absolute, Steady-State Measurements

The thermal conductivity of polycrystalline magnesium oxide has been measured over the temperature range from 400 K to 1300 K using a modified guarded-hot-plate design. Three different thicknesses of specimens having 93 % of theoretical density were tested to verify the operation, accuracy, and reproducibility of our apparatus. The measured thermal conductivity ranges from 30 W · m-1 · K-1 down...

متن کامل

Development of the Measurement Apparatus for the Effective Thermal Conductivity of Core Material

A measurement apparatus is designed and fabricated to measure the effective thermal conductivity (keff) of a VIP (vacuum insulation panel) core specimen under various vacuum states and external loads. The apparatus consists of part for measuring keff, and parts for controlling external load and vacuum condition. Uncertainty of the apparatus is validated by measuring the standard reference mater...

متن کامل

A New Facility for the Experimental Investigation on Nano Heat Transfer between Gas Molecules and Ceramic Surfaces

Since the last decade, the interest has risen in nanoscaled technological products, which have advantages through their size effect. The size effect also plays a significant role in the area of microand nanoscale heat transfers. Many applications were developed using this effect, such as nanostructured porous media, e.g. Aerogels or ceramics. This experimental work is focused on the determinati...

متن کامل

Measurement of the Figure-of-merit of Thermoelectric Devices

The apparatus for evaluation of the figure of merit (ZT) of thermoelectric devices has been developed. ZT value is comprised of three physical quantities, Seebeck coefficient, electrical conductivity, and thermal conductivity. However, to date, the ZT values of the thermoelectric devices have been evaluated by Harman method due to difficulty in measuring thermal conductivity of the devices with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015