Comparison of the Du Pont aca and Dow methods for determination of high-density lipoprotein cholesterol.

نویسندگان

  • N N Rehak
  • R J Elin
  • R Chesler
  • E Johnson
چکیده

We compared the Du Pont aca (phosphotungstate-enzymic cholesterol) and the Dow (dextran sulfate/Mg2+-enzymic cholesterol) methods for the determination of high-density lipoprotein cholesterol (HDLC) and total cholesterol in serum from 113 patients. The aca results for both total cholesterol and HDLC were significantly greater (p less than 0.0001) than the Dow results, the aca method overestimating the HDLC concentration (mean recovery 107.2% in serum samples with values assigned by the Centers for Disease Control). The precision of the aca method for HDLC was essentially the same as that of the Dow method. Bilirubin (up to 0.17 g/L), hemoglobin (up to 4 g/L), and slight lipemia (triglycerides up to 5.4 g/L) did not interfere with the aca method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation and comparison of a radiative energy attenuation method for determining cholesterol in serum.

Determination of cholesterol by a radiative energy attenuation (REA) technique was evaluated and compared with results obtained by the Boehringer Mannheim High Performance Cholesterol Assay and the Du Pont aca. Within-assay and between-assay CVs for the REA method, for two sets of controls, were both less than 5%. We observed no interference with lipemic samples. Analytical recovery averaged 10...

متن کامل

A spectrometric version of the total bilirubin determination with the Du Pont ACA with respect to neonatal sera.

A spectrometric modification of the determination of total bilirubin with the Du Pont ACA is described. Accuracy, precision and standardization problems are discussed in comparison with the earlier published diazo modification, as well as other techniques well known in the field of neonatal chemistry.

متن کامل

Enzymic serum cholesterol measurement with a basic autoanalyzer and Du Pont aca method.

I compared enzymic methods for total serum cholesterol as used with discrete (Du Pont aca and reagent packs) and continuous-flow (Boehringer Mannheim reagents and the Technicon AuotAnalyzer I) analysis of normal, icteric, and lipemic sera. The regression equation for 24 clear, non-icteric sera was: y (continuous flow) = 0.944x (aca) + 10.69; r = 0.971, Syx +/- 53.7 mg of cholesterol per liter. ...

متن کامل

Evaluation of three current methods for the determination of creatine kinase-MB catalytic activity.

Three current methods for the determination of the creatine kinase-MB activity were evaluated: electrophoresis (Beckman Inst.), ion-exchange MB-Zyme (J.T. Baker) and ion-exchange on aca (Du Pont). Eighty patients were selected out of three groups: acute myocardial infarction, heart and vascular surgery patients and a number of noncardiac cases. The precision of the ion-exchange methods was comp...

متن کامل

High-Density Lipoprotein Measurement Methods: From Precipitation to Nuclear Magnetic Resonance (NMR)

Introduction: Extensive research suggests a common hypothesis regarding the protective role of total high-density lipoprotein-cholesterol (HDL-C) against cardiovascular disease (CVD). This hypothesis indicates an inverse relationship between CVD and high HDL-C levels. Various mechanisms, such as reverse cholesterol transport, besides anti-inflammatory and antioxidant functions, indicate HDL-C a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 1984